Gas Connection; Data Plate - Hotpoint Ariston PO 740 ES Operating Instructions Manual

Hide thumbs Also See for PO 740 ES:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 22
 Once the appliance has been installed, the power supply
GB
cable and the electrical socket must be easily accessible.
 The cable must not be bent or compressed.
 The cable must be checked regularly and replaced by
authorised technicians only (see Assistance).
 The manufacturer declines any liability should these
safety measures not be observed.

Gas connection

The appliance should be connected to a gas cylinder in
compliance with current directives. On some models the
gas supply can be connected on the left or on the right,
as necessary; to change the connection, reverse the
position of the hose holder with that of the cap and
replace replace the gasket (supplied with the appliance).
Remember to install a pressure regulator on the LPG
cylinder, which complies with current directive.
 check that the supply pressure complies with the values
indicated in table 1 “Characteristics of the burners and
nozzles” since this will ensure safe operation, correct
consumption and ensure a longer life to your appliance.
Connection with hose
Make the connection using a gas hose complying with the
the characteristics provided in current directive. The
internal diameter of the pipe used is as follows:
- 8mm for liquid gas;
When installing the hose, remember to take the following
precautions:
Check that the hose fits firmly into place at the two ends
and fix it with clamps complying to current directive.If any
of the above recommendations can not be adopted,
flexible metal pipes should be used.
Tight control
 When installation has been completed, check the pipe
fitting for leaks with a soapy solution. Never use a flame.
Once the connection has been made, ensure that the
flexible metal tube does not touch any moving parts and
is not crushed.
Regulation of Air Supply to the Burner
The burners do not need a primary air regulator.
24
Connecting the supply cable to the mains
Install a normalised plug corresponding to the load
indicated on the data plate. When connecting the cable
directly to the mains, install an omnipolar circuit-breaker
with a minimum contact opening of 3 mm between the
appliance and the mains. The omnipolar circuit breaker
should be sized according to the load and should comply
with current regulations (the earth wire should not be
interrupted by the circuit breaker).
The supply cable should be positioned so that it does not
reach a temperature of more than 50°C with respect to the
room temperature, along its length. Before making the
connection, check that:
1. the limiter valve and the home system can support the
appliance load (see data plate);
2. the mains is properly earthed in compliance with current
directives and regulations;
3. there is easy access to the socket and omnipolar circuit
breaker, once the hob has been installed.
 never use reducers, adaptors or shunts since they can
cause heating or burning.

DATA PLATE

Electrical
220-240V ~ 50/60Hz
connections
This appliance conforms to the
following European Economic
Community directives:
-73/23/EEC dated 19/02/73 (Low
Voltage) and subsequent
amendments
- 89/336/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 90/336/EEC dated 29/06/90
(Gas) and subsequent
amendments.
- 2002/96/EC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Po 740 ha

Table of Contents