Problem
Camera does not
take a picture
Housing is hard to
close
Fogging occurs on
the Lens Port
Solution
- Install a fully charged battery.
- There is not enough available light for the camera
to properly focus. Add a focusing light or strobe
with a built-in focusing or video light to your
system.
- Select a center focus point in your camera menu.
- Return Zoom control to the "disengaged" position,
see Zoom Control Use, page 12.
- Make sure the camera is mounted properly in the
housing and controls are out of the way.
- Main housing o-ring is not seated properly.
- Hotshoe cord is in the way.
- Step Ring is not engaging housing gear properly.
- Humid air is trapped inside the housing.
The camera produces heat and may condense
any trapped moisture forming fog on the lens port.
Close the housing in an air-conditioned room or
vehicle, or in front of an air-conditioner.
- The housing should not be in direct sunlight for an
extended period of time.
- Purchase desiccant packs also known as
moisture munchers from a local camera store.
Place one or two new packs in your housing
before each day of diving.
- If moisture or water droplets are present around
the controls or sealing areas, return the housing
to Ikelite for evaluation.
- Clean the main housing o-ring and sealing
surface of the housing.