  • Page 1       INSTRUCTION MANUAL INSTALLATION / OPERATION / PARTS & SERVICE MODELS:     SB36 & SB3618                ...
  • Page 2: Notification

      IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INTIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
  • Page 3: Table Of Contents

      TABLE OF CONTENTS NOTIFICATION ..... . .1 TABLE OF CONTENTS ....2 INTRODUCTION .
  • Page 4: Introduction

        TOOLS GENERAL  Standard set of hand tools Montague Gas Salamander Broilers are manufactured for use with the type of gas  Gas leak detection equipment indicated on the data plate (natural or propane).  Gas pressure manometer Installation Refer to the Installation portion of this manual.
  • Page 5: Installation

    The gas salamander broiler is manufactured for use with the type of gas indicated on the nameplate. The Montague gas salamander broilers are produced with the best possible material and workmanship. PROPER INSTALLATION IS ESSENTIAL FOR SAFE AND EFFICIENT TROUBLE-FREE OPERATION.
  • Page 6: Clearances & Ventilation

      INSTALLATION Information on construction and installation of ventilating hoods may be obtained from the “Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors No. 96 - available from the National Fire Protection Association Batterymarch Park, Quincy, Ma.
  • Page 7: Mounting & Leveling

      FLUE BASE ACCEPTS HIGH BACK POSTS MODEL SB36 TECHNOSTAR     Unit must be mounted on a reinforced high shelf on any 36” wide Model T26, VT26, T260, T2616, T1626 series Montague Technostar range as follows:      ...
  • Page 8: Gas Connections

      INSTALLATION      ...
  • Page 9: Gas Connection Notice

      INSTALLATION  ...
  • Page 10: Operations

      OPERATIONS 4. If pilot becomes extinguished, turn Burner Valve to the Off position and wait (5) minutes before relighting.  ...
  • Page 11   OPERATIONS NOTE: Model SB3618 is manufactured with a throttling burner. Turn Main Burner Valve clockwise to close or adjust burner flame down or counter clockwise to open or adjust burner flame up.  ...
  • Page 12: Cleaning & Maintenance

      CLEANING & MAINTENANCE Montague equipment is sturdily constructed of the best materials and is designed to provide durable service when treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and cleaned daily.
  • Page 13: Service & Adjustment Procedures

      SERVICE & ADJUSTMENT PROCEDURES  WARNING WHEN SERVICE IS NEEDED, CONTACT A LOCAL SERVICE COMPANY, DEALER OR FACTORY TO PEERFORM MECHANICAL MAINTENANCE AND RE- PAIRS. THESE INSTRUCTIOS ARE INTENDED FOR USE BY COMPETENT SERVICE PERSONNEL. CAUTION TURN OFF GAS AT THE MANUAL OR AUTO- MATIC SHUT OFF VALVE CONTROLING THE APPLIANCE BEFORE ATTEMPTING TO LOOSEN ANY GAS CONNECTIONS.
  • Page 14: Covers & Panels

        SERVICE & ADJUSTMENT PROCEDURES                           ...
  • Page 15: Pilot Adjustment & Pilot Burner Valve

      SERVICE & ADJUSTMENT PROCEDURES              ...
  • Page 16: Pilot Orifice & Main Burner Valve

        SERVICE & ADJUSTMENT PROCEDURES        ( ALLEN HEAD SET SCREW)                  ...
  • Page 17: Main Burner Orifice

      SERVICE & ADJUSTMENT PROCEDURES SB 36 SB 3618 SB 3618 MAIN BURNER PARTS A. Main burner orifice Unscrew orifice from valve to remove debris. Replace if needed. B. Air Shutter Clean shutter opening of lint and debris. Adjust shutter open or closed until desired flame is achieved.
  • Page 18: Tube & Gear Assembly

      SERVICE & ADJUSTMENT PROCEDURES                ...
  • Page 19: Carriage Frame Handle

      SERVICE & ADJUSTMENT PROCEDURES            ...
  • Page 20: Pressure Regulator & Pilot Burner

             ...
  • Page 21: Pilot Valve, Carriage Adjustments

               ...
  • Page 22: Trouble Shooting Chart

               ...
  • Page 23: Exploded View Sb36

               ...
  • Page 24: Parts List Sb36

            Valve Handle w/ Set Screw ‐ ( For Technostar  p/n 50689‐3)  (For Units prior to 02/09 p/n  2002‐8)  38485-2                ...
  • Page 25: Carriage Stabalizer Components

      CARRIAGE STABALIZER COMPONENTS “C” Hook Spring Retention P/N 1956-9   Spring, Carriage Tension P/N 2035-4 Stabalizer Control Arms are Non- Serviceable Eye Bolt P/N 1938‐0        ...
  • Page 26: 3618 Burner Assembly

      SALAMANDER BROILER 3618 BURNER ASSEMBLY ITEM # DESCRIPTION PART NUMBER BURNER FRAME 4382-6 CERAMIC KIT 28387-8 BURNER ASSEMBLY 4276-5 VENTURI W AIR MIXER 26940-9 BURNER GASKET 20923-6 NOTE* Burner Gasket (item #5) should always be replaced when servicing burner. SB36 BURNER ASSEMBLY KEEP VENTURI CLEAR OF GREASE &...
  • Page 27: 3618 Manifold Assembly

      SALAMANDER BROILER 3618 MANIFOLD ASSEMBLY 4  5  2  3  1  6  7  9  8  ITEM # DESCRIPTION PART NUMBER 7341‐5  MANIFOLD   ELBOW - STREET, PIPE 14666-8 #3  PIPE COUPLING 2651-4 #4  VALVE / LESS HOOD 2569-0 #5  PIPE UNION 1187-8 PIPE NIPPLE 1146-0...
  • Page 28: Notes

             ...
  • Page 29: Notice

               ...
  • Page 30: Back

      P/N 9326-2 REV. - A 6/11      ...