IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INTIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
TOOLS GENERAL Standard set of hand tools Montague Gas Salamander Broilers are manufactured for use with the type of gas Gas leak detection equipment indicated on the data plate (natural or propane). Gas pressure manometer Installation Refer to the Installation portion of this manual.
The gas salamander broiler is manufactured for use with the type of gas indicated on the nameplate. The Montague gas salamander broilers are produced with the best possible material and workmanship. PROPER INSTALLATION IS ESSENTIAL FOR SAFE AND EFFICIENT TROUBLE-FREE OPERATION.
INSTALLATION Information on construction and installation of ventilating hoods may be obtained from the “Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors No. 96 - available from the National Fire Protection Association Batterymarch Park, Quincy, Ma.
FLUE BASE ACCEPTS HIGH BACK POSTS MODEL SB36 TECHNOSTAR Unit must be mounted on a reinforced high shelf on any 36” wide Model T26, VT26, T260, T2616, T1626 series Montague Technostar range as follows: ...
OPERATIONS 4. If pilot becomes extinguished, turn Burner Valve to the Off position and wait (5) minutes before relighting. ...
Page 11
OPERATIONS NOTE: Model SB3618 is manufactured with a throttling burner. Turn Main Burner Valve clockwise to close or adjust burner flame down or counter clockwise to open or adjust burner flame up. ...
CLEANING & MAINTENANCE Montague equipment is sturdily constructed of the best materials and is designed to provide durable service when treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and cleaned daily.
SERVICE & ADJUSTMENT PROCEDURES WARNING WHEN SERVICE IS NEEDED, CONTACT A LOCAL SERVICE COMPANY, DEALER OR FACTORY TO PEERFORM MECHANICAL MAINTENANCE AND RE- PAIRS. THESE INSTRUCTIOS ARE INTENDED FOR USE BY COMPETENT SERVICE PERSONNEL. CAUTION TURN OFF GAS AT THE MANUAL OR AUTO- MATIC SHUT OFF VALVE CONTROLING THE APPLIANCE BEFORE ATTEMPTING TO LOOSEN ANY GAS CONNECTIONS.
SERVICE & ADJUSTMENT PROCEDURES SB 36 SB 3618 SB 3618 MAIN BURNER PARTS A. Main burner orifice Unscrew orifice from valve to remove debris. Replace if needed. B. Air Shutter Clean shutter opening of lint and debris. Adjust shutter open or closed until desired flame is achieved.