Config.ini File Content (Continued)
Table 1-1
Name
ScanParam
Separator
Sleep
Suffix
TimeFormat
WakeUpBeep
WakeUpLED
ZeroOutHIDClassOfDevice
Description
Any scanner parameter. Multiple entries are
allowed. Sent after reset or whenever
scanner is powered.
For example:
ScanParam=0xf0,0x00,0x01
ScanParam=0xee,0x01
ScanParam=0x38,0x00
Separator character
Time in seconds before device enters sleep
mode if no activity is detected
Add suffix to decode data
Time format for data stored in batch
Enable or disable wake up beep
Enable or disable wake up LEDs
Some versions of Broadcom stack
experience issues when connecting to HID
devices. Enable this feature if this is the
case.
Getting Started 1 - 11
Values
Variable
N/A
Byte
','
Word
0
Byte
<none>
1 = 12h
24h
0 = 24h
1 = Enabled
Disabled
0 = Disabled
1 = Enabled
Disabled
0 = Disabled
1 = Enabled
Disabled
0 = Disabled
Default