Memory Switch Settings - Star SM-S201 Hardware Manual

Sm-s200 series
Hide thumbs Also See for SM-S201:
Table of Contents

Advertisement

2.5. Memory Switch Settings

1. Change the Memory switch by this operation. (Refer to Table 1).
MODE button : changing Printer MODE status
FEED button : changing OPTION status.
2. [Example] The defaults of the printer are :
Bluetooth/57600 bps/8 Data bit/No Parity/1 Stop bit/Density Medium
If a user wants to change the defaults with
RS-232C/9600 bps/7 Data bit/Even Parity/2 Stop bit/Density High
u After pressing the MODE button simultaneously, if the ERROR lamp 5 turn
signals MODE button is converted with MODE functions
g You will see present COMMUNICATION mode in the LCD.
g Press the MODE button one time.
(The interface mode has set to RS-232C mode.)
Bluetooth g RS-232C
u Press FEED button one time.
g You will see present BAUD RATE mode in the LCD.
Communication Port g Baud Rate
g Press the MODE Button twice.
(The baud rate has set to 9600 bps)
57600 bps g 115200 bps g 9600 bps
u Press FEED button one time.
g You will see present DATA BIT mode in the LCD.
Baud Rate g Data Bit
g Press the MODE button one time.
(The data bit has set to 7 data bit.)
8 Data Bit g 7 Data Bit
u Press FEED button one time.
g You will see present PARITY BIT mode in the LCD.
Data Bit g Parity Bit
g Press the MODE button twice.
(The parity bit has set to even parity bit.)
No Parity gEven Parity