REAR FLUE EXIT

Boiler Model

For the rear flue outlet configuration, push in the flue
connector pipe (not supplied) into the flue outlet
socket at the rear of the stove and cement into place
using approved fire cement ensuring that no cement
blocks the flue passageway. (See Fig.4)
Fig.6
Fig 3

LOCATION

There are several conditions to be considered in
selecting a location for your Grainne Stove.
a. Position in the area to be heated- central
locations are usually best.
b. Allowances for proper clearances to
combustibles.
Note: Sufficient space should be given around
Fig. 4
the back and sides of the stove to allow
access to the air control damper.

INSTALLATION CLEARANCES

Maintain at least the following clearances to all
combustible material:
Boiler Model
From the front
From the back
From the sides
From the flue pipe
Non Boiler Model
From the front
From the back
Fig. 5
From the sides
From the flue pipe
It is recommended that this appliance is sited next to
and on a non-combustible surface. A minimum all
round clearance of 100 mm will allow air circulation
and not impede the performance of the stove.

FLOOR PROTECTION

It is recommended that this appliance is installed on
a solid, level, non combustible hearth conforming to
current Building Regulations.
6
910 mm
150 mm
150 mm
910 mm
910 mm
800 mm
800 mm
910 mm