ASSEMBLY INSTRUCTIONS

Blower Assembly

THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE
ATTEMPTING THE INSTALLATION.
THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE.
DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES!
Step 1.
Fix the assembly to the back of the stove with the four screws provided.
Pedestal Trim Assembly
Assemble trim pieces as shown with the screws provided
in the parts bag. Washers may not be necessary.
After trim assembly, attach to the pedestal base at
the location shown using the screws provided.
6
Ash Pan Assembly
Remove ash pan from firebox. Under the firebox, there
are two brackets; Slide the ash pan into these brackets.
Ussc

Advertisement

Table of Contents
loading

Summary of Contents for United States Stove Company 2000

  • Page 1: Assembly Instructions

    ASSEMBLY INSTRUCTIONS Blower Assembly THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING THE INSTALLATION. THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE. DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES! Step 1.
  • Page 2: Installation

    INSTALLATION SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. • CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS AND INSTALLATIONS REQUIREMENTS IN YOUR AREA. • USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED. • KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE. • NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN...
  • Page 3: Floor Protector

    1/8” mineral board K=0.29, R=1/0.29 x 0.125=0.431 Total R = Rbrick + Rmineral = 0.8 + 0.431 = 1.231 Total R is greater than 1.2, the system is acceptable. The floor protector should exceed the stove as follows: Model Front Sides Rear 2000 25” 8” ¶6” (635mm) (203mm) (152mm) 2500 26”...
  • Page 4: Clearances To Combustibles

    CLEARANCES TO COMBUSTIBLES It is of utmost importance that the clearances to combustible materials be strictly adhered to during installation of the stove. Refer to the tables below : Single Wall Pipe (Double Wall Pipe) Model A 2000 20(14) 22(20) 22.5(16.5) 32(30)
  • Page 5: Chimney Connector (Stove Pipe)

    CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have the same diameter as the stove outlet (6”). If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draft.
  • Page 6 CHIMNEY Your wood stove may be hooked up with a 6” factory built or masonry chimney. If you are using a fac- tory built chimney, it must comply with UL 103 or CSA-B365 standard; therefore it must be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer’s specifications. If you are using a masonry chimney, it is important that it be built in compliance with the specifica- tions of the National Building Code. It must be lined with fire clay bricks, metal or clay tiles sealed together with fire cement. (Round flues are the most efficient). The interior diameter of the chimney flue must be identical to the stove smoke exhaust. A flue which is too small may cause draft problems, while a large flue favours rapid cooling of the gas, and hence the build-up of creosote and the risk of chimney fires. Note that it is the chimney and not the stove which creates the draft effect; your stove’s performance is directly dependent on an adequate draft from your chimney.
  • Page 7: Factory Built Chimney

    FACTORY BUILT CHIMNEY : When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation.
  • Page 8: Masonry Chimney

    MASONRY CHIMNEY : Ensure that a masonry chimney meets the minimum standards of the National Fire Protection As- sociation (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chim- ney, special methods are needed.
  • Page 9 Combustible Wall Chimney Connector Pass-Throughs Method A. 12” (304.8 mm) Clearance to Combustible Wall Mem- ber: Using a minimum thickness 3.5” (89 mm) brick and a 5/8” (15.9 mm) minimum wall thickness clay liner, construct a wall pass- through. The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) or its equivalent. Keep a mini- mum of 12”...
  • Page 10: Outside Combustion Air

    OUTSIDE COMBUSTION AIR Your wood stove is approved to be installed with an outside air intake which is necessary for a mobile home. This type of installation is also required in air tight houses and houses with negative pressure problems. You can purchase this option through your heater dealer. Make sure to specify the part number mentioned in this booklet.
  • Page 11: Woodstove Utilization

    WOODSTOVE UTILIZATION Your heating unit was designed to burn wood only; no other materials should be burned. Waste and other flammable materials should not be burned in your stove. Any type of wood may be used in your stove, but specific varieties have better energy yields than others. Please consult the following table in order to make the best possible choice. TYPE WEIGHT PER CORD EFFICIENCY SPLITS MILLIONS (LBS. CU. FT., RANKING BTU’s/CORD DRY) Hickory 4500 Well 31.5 White Oak 4100 Fair 28.6...
  • Page 12: The First Fires

    When you have achieved a good bed of hot embers, we recommend the following burn procedures: 2000 Primary Air Settings...
  • Page 13 WARNINGS • NEVER OVERFIRE YOUR STOVE. IF ANY PART OF THE STOVE STARTS TO GLOW RED, OVER FIRING IS HAPPENING. READJUST THE AIR INTAKE CONTROL AT A LOWER SETTING. • THE INSTALLATION OF A LOG CRADLE or GRATES IS NOT RECOMMENDED IN YOUR WOOD STOVE. BUILD FIRE DIRECTLY ON FIREBRICK. • NEVER PUT WOOD ABOVE THE FIREBRICK LINING OF THE FIREBOX. RELOADING Once you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air controls to maximum a few seconds prior to opening the stove’s door.
  • Page 14: Ash Disposal

    ASH DISPOSAL Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold, such as in the morning. Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the close...
  • Page 15: Repair Parts

    REPAIR PARTS 32 33 Feed Door Assembly Ussc...
  • Page 16 5/16-18 x 3/4 Hex Head Bolt 891530 Firebrick (4-1/2 x 7-1/2 ) 83338 5/16-18 Lock Nut 40561 Ash Plug 891373 Door Hinge Pad 891777 2000 Pedestal Wrapper 83045A Washer, 3/8” ID x 7/8” OD 891788 2500 83274 3/8-16 Lock Nut 891778 2000...
  • Page 17 NOTES Ussc...
  • Page 18 NOTES Ussc...
  • Page 19: How To Order Repair Parts

    HOW TO ORDER REPAIR PARTS THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS COR- RECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFOR- MATION AS SHOWN IN THIS LIST: 1. THE PART NUMBER 2. THE PART DESCRIPTION 3. THE MODEL NUMBER: _______________________ 4. THE SERIAL NUMBER: _______________________ UNITED STATES STOVE COMPANY 227 INDUSTRIAL PARK ROAD P.O. BOX 151 SOUTH PITTSBURG, TN 37380 (423) 837-2100 WWW.USSTOVE.COM Ussc...

Table of Contents