  • Page 1 CMS60C Pulse Oximeter Pulse Oximeter Pulse Pulse Oximeter Oximeter CONTEC MEDICAL SYSTEMS CO., LTD...
  • Page 2 Instructions Instructions to to to to User User Instructions Instructions User User Dear users, thank you very much for purchasing the Pulse Oximeter. This Manual is written and compiled in accordance with the council directive MDD93/42/EEC for medical devices and harmonized standards. In case of modifications and software upgrades, the information contained in this document is subject to change without notice.
  • Page 3: Table Of Contents

    C C C C ontents ontents ontents ontents 1Safety 1Safety 1Safety 1Safety..........................................................................................................................................1 1 1 1 1.1Instructions for safe operations........................1.2Warning................................. 1.3Attention................................2.Overvi ew 2.Overvi ew 2.Overvi ew 2.Overvi ew....................................................................................................................................2 2 2 2 2.1Features.................................
  • Page 4: Instructions For Safe Operations

    1 1 1 1 Safety Safety Safety Safety Instructions safe operations 1.1 Instructions Instructions Instructions for for safe safe safe operations operations operations � Check the main unit and all accessories periodically to make sure that there is no visible damage that may affect patient’s safety and monitoring performance about cables and transducers.
  • Page 5: Features

    ␇ The pulse oximeter can be used to adult or infant. Whether the device is used to adult or infant,it depends on the probe selected. ␇ The update period of data is less than 5 seconds, which is changeable according to different individual pulse rate.
  • Page 6: Environment Requirements

    problem problem problem of of of of overrating overrating overrating would would emerge emerge when when patient patient patient is is is is suffering suffering suffering from from toxicosis toxicosis The problem overrating would would emerge emerge when when the the patient suffering from from toxicosis...
  • Page 7: Main Parameters

    H H H H ..With alarm function I I I I ..With SpO value and pulse rate value of storage, the stored data can be uploaded to computers J J J J ..It can be connected with an external oximeter probe K K K K .
  • Page 8: View Of Of Of Of The

    5 5 5 5 Installation Installation Installation Installation View View View of of of of the front front panel panel 5.1 View the front front panel panel Figure 2. Front View Underside View Left View 5.2 Underside Underside Underside View View View and and Left...
  • Page 9: Accessories

    5. 5. 5. 5.4 4 4 4 Accessories Accessories Accessories Accessories A. A. A. A. A lithium battery(Model: GSP053759, rated voltage 3.7V, capacity1050mAh) B. B. B. B. A User Manual C. C. C. C. A power adapter D. D. D. D. A data line E.
  • Page 10 B. B. B. B. Change Change Change Change display display display display direction: direction: direction: direction: On the measuring interface, press the"screen change button"can change the display direction. C. C. C. C. Pause Pause Pause alarm: alarm: Pause alarm: alarm: a) a) a) a) Alarm including the alarm of measure data's going beyond the limits, the alarm of low-voltage, the alarm of probe or finger's out of position.
  • Page 11 measurement measurement measurement measurement shows shows shows shows in in in in yellow. yellow. yellow. yellow. Medium priority indicating that prompt operator response response is is is is required. required. Medium Medium Medium priority priority priority indicating indicating indicating that that that prompt prompt...
  • Page 12 b. b. b. b. When the"Start"is displayed on the menu,if the memory still have the former data in storage ,the " Do you really want to recover the memory" dialog box will be displayed when pressing the "menu"button ,then press the"up button"or"down button"to choose setting,then press the"menu button"to confirm setting,the dialog box will be displayed as figure 10:It needs to set the starting time for data storage by users, users can change the setting value by pressing the"up button"or"down button",and confirm the setting value by pressing the"menu button",the black cursor will move to...
  • Page 13 Figure 12. SpO2 Review program a. a. a. a. Please connect the device to computer with the affiliated data line , then double click"SpO2 Review"icon to start the program. b. b. b. b. On the main menu interface,press the"up button"or"down button" in order to move the menu choice bar to"Upload",then press the"menu button"to transmit the stored data to computer for replay and analysis.
  • Page 14: Attention For Operation

    Power supply by battery only, and battery status is full Battery status is not full Battery status is draining away Low power alarm indication(Please charge the battery ) the four status above shows Battery is under charging dynamically in turn d d d d )...
  • Page 15: Storage

    thiosalicylic hemoglobin, and some with icterus problem, the SpO determination by this monitor may be inaccurate. C C C C ..The drugs like dopamine, procaine, prilocaine, lidocaine and butacaine may also be a major factor blamed for serious error of SpO measure.
  • Page 16: 9Key Of Of Of Of Symbols

    display display is is is is off The display display The battery is drained away or almost Please recharge the battery suddenly suddenly suddenly suddenly drained away . device device The device device can can not 1. Please recharge the battery 1.The battery is not full charged.
  • Page 17: 10Function 10Function Specification Specification

    Serial number 1. the finger clip falls off ( no finger inserted)] 2. Probe error 3. Signal inadequacy indicator IPX1 Ingress of liquids rank WEEE (2002/96/EC) This item is compliant with Medical Device Directive 93/42/EEC of June 14, 1993, a directive of the European Economic Community. 10 10 10 10 Function Function Function...
  • Page 18 Continuous bar-graph display, the higher display Range indicate the stronger pulse. Battery Battery Requirement Requirement Battery Battery Requirement Requirement Voltage 3.7 rechargeable lithium battery × 1 Batter Batter Batter Battery y y y working working working working life life life life Charge and discharge no less than 500 times.
  • Page 19: Appendix1

    The Pulse Oximeter(CMS60C) is intended for use in the electromagnetic environment specified below. The customer of the user of the Pulse Oximeter(CMS60C) should assure that it is used in such an environment Emission Emission test...
  • Page 20 The Pulse Oximeter(CMS60C) is intended for use in the electromagnetic environment specified below. The customer or the user of the Pulse Oximeter(CMS60C) should assure that it is used in such an environment Compliance Compliance Compliance Compliance...
  • Page 21: Appendix2

    The Pulse Oximeter(CMS60C) is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Pulse Oximeter(CMS60C) can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Pulse Oximeter (CMS60C) as recommended below, according to the maximum output power of the communications equipment.