Diagnostic Stripe - Oce Arizona T220UV User Manual

Hide thumbs Also See for Arizona T220UV:
Table of Contents

Advertisement

Diagnostic Stripe

Introduction
The Diagnostic Stripe is an option that can be turned on or off in the Print Parameter menu. If the option is turned on, then
on the first swath of printing, a stripe is printed on the away side of the image. The stripe is printed every time the gantry has
stepped approximately 250mm. This stripe can yield a lot of detailed information similar to the diagnostic nozzle print
regarding the position and condition of the heads.
Make sure the media is large enough to allow the stripe to print on the away side. Otherwise the stripe may print on
Note:
the table. Alternately, use a piece of scrap media of the same thickness to print the stripe on.
Illustration
[8] Diagnostic Stripe
[8] Diagnostic Stripe
Nozzle Order
Each head has a row of 128 nozzles. The outer nozzles are not fired in the image or in the Diagnostic Stripe. Due to the nature
of the head, adjacent nozzles can't be fired at the same time. Nozzles are labeled in the following order:
Outer Nozzle A B C A B C ........... A B C A B C Outer Nozzle
1 • • • • • • • • • • • • • • • • .............• • • • • • • • • • • • • • 128
How to Operate the Arizona T220UV
53

Advertisement

Table of Contents
loading

Table of Contents