Diagram 9
front of the masonry, use wood screws to
mount the Wall Thimble Cover to the framed
wall, over the Retro Connector and the 10"
(254mm) square framed opening. Diagram
11. If needed, add a section of direct vent
pipe to the Retro Connector in order to extend
through the opening in the Wall Thimble
Cover.
10. The connection between the appliance and
the Retro Connector may be completed with
a section of black direct vent pipe, together
with an adjustable length pipe section.
Diagram 10
Diagram 11

System Data

U39 with 40,000 BTU
U39-NG10: For 0 to 2000 feet altitude
U39-LP10: For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes:
Natural Gas
Burner
#32
Max. Input - Natural Gas/Propane
38,000 Btu/h
Min. Input - Natural Gas/Propane
20,000 Btu/h
Supply Pressure
Natural Gas
min. 5" w.c.
Propane
min. 12" w.c.
Manifold Pressure
Natural Gas
3.8"
Propane
11"
Manifold Pressure
Natural Gas
3.8"
Propane
11"
Electrical: 115V._60Hz.less than 2 AMP
Circulation: Variable speed fan, 125/75 CFM.
Log Set: Ceramic fiber, 7 per set.
System Data:
HIGH ELEVATION - U39-NG10
For 2,000 - 4,500 feet altitude
Conversion Kit # 730-920
Burner Inlet Orifice Sizes:
Natural Gas
Burner
Max. Input Rating 36,100 Btu/h
Min. Input Rating 19,000 Btu/h
System Data
U39-10 Converted to 30,000 Btu
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes:
Natural Gas
Burner
#37
Max. Input - Natural Gas/Propane
30,000 Btu/h
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes:
Natural Gas
Burner
#37
Max. Input - Natural Gas/Propane
30,000 Btu/h
Min. Input - Natural Gas/Propane
15,000 Btu/h
Supply Pressure
Natural Gas
min. 5" w.c.
Propane
min. 12" w.c.
Manifold Pressure
Natural Gas
3.8"
+/- 0.2" w.c.
Propane
11"
+/- 0.2" w.c.
Electrical: 115V._60Hz.less than 2 AMP
Circulation: Variable speed fan, 125/75 CFM.
Log Set: Ceramic fiber, 7 per set.
Regency
®

GAS CONNECTION

The gas connection is a 3/8" NPT 90
line can be rigid pipe or to make installation easier,
use a listed flexible connector and/or copper tubing
if allowed by local codes. Since some municipalities
have additional local codes it is always best to
Propane
consult with your local authorities and the CAN/
#50
CGA B149 installation codes.
For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.
When using copper or flex connectors use only
approved fittings. Always provide a union so that
gas lines can be easily disconnected for burner
and/or valve servicing. Flare nuts for copper lines
and flex connectors are usually considered to meet
this requirement.
+/- 0.2" w.c.
+/- 0.2" w.c.
Important: Always check for gas leaks with a
soap and water solution or gas leak detector.
+/- 0.2" w.c.
Do not use open flame for leak testing.
+/- 0.2" w.c.
Note: Prior to any pressure testing of the gas
supply piping system that exceeds test
pressures of 1/2 psig, this appliance must
be disconnected from the piping system.
If test pressures equal to or less than 1/2
psig are used then this appliance must
be isolated from the piping system by
closing its individual manual shut-off
valve during the testing.
#33

HIGH ELEVATION

This unit (at 38,000 Btu/h) is approved in Canada
for altitude 2000 ft. to 4500 ft. (CAN/CGA-2.17-M91.
with the orifice kit Part # 621-975. For Natural Gas
installations above 4500 ft. follow current CAN/
CGA-B149.1.
Propane
#52
In U.S.A., for installations above 2000 ft. refer to
current ANSI Z223.1 Sc8-8.1.2a appendix F, for
resizing orifice.
Propane
#52
U39-10 ULTIMATE Direct Vent Freestanding Gas Stove