Self Powered
User's Manual
Benutzer Handbuch
Important Information,
Wichtige Informationen,
Please Read Before Use!
vor Inbetriebnahme lesen!
KLING
KLING
Junkersstrasse 14
Junkersstrasse 14
D-30179 Hannover
D-30179 Hannover
PHONE 0 (049) 511- 969 97-0
TEL 0 (049) 511- 969 97-0
FAX 0 (049) 511- 67 37 94
FAX 0 (049) 511- 67 37 94
www.kling-freitag.de
www.kling-freitag.de
'SP' Models based upon the CA Series
FREITAG GmbH
&
FREITAG GmbH
&
<0}
Version 6.1
Released: 23.03.2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CA 1001 - SP and is the answer not in the manual?

Questions and answers

Summary of Contents for KLING & FREITAG CA 1001 - SP

  • Page 1 Self Powered ‘SP’ Models based upon the CA Series Version 6.1 Benutzer Handbuch User's Manual <0} Released: 23.03.2006 Important Information, Wichtige Informationen, Please Read Before Use! vor Inbetriebnahme lesen! KLING FREITAG GmbH & KLING FREITAG GmbH & Junkersstrasse 14 Junkersstrasse 14 D-30179 Hannover D-30179 Hannover PHONE 0 (049) 511- 969 97-0...
  • Page 2 User's Manual ‘SP’ Models based upon the CA Series KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 2 of 54...
  • Page 3 User’s Manual ‘SP’ Models based upon the CA Series Thank you for your decision to buy a Kling & Freitag sound system. To guarantee a trouble-free operating of the equipment and to allow the KLING & FREITAG -- - ‘SP’ speaker system to achieve its full potential please read the operating instructions care- fully before use.
  • Page 4: Table Of Contents

    10. Operating the Speakers 11. Touching Up Damage to Paint / Changing the Front Foam 12. Block Diagram of the SP Full-Range Speaker 13. Technical Specifications 13.1 CA 1001 - SP 13.2 CA 1201 - SP 13.3 CA 1215-6 - SP 13.4...
  • Page 5 User’s Manual ‘SP’ Models based upon the CA Series Chapter Page 14. Measuring Charts 14.1 CA 1001 - SP 14.2 CA 1201 - SP 14.3 CA 1215-6 - SP 14.4 CA 1215-9 - SP 14.5 CA 1515-6 - SP 14.6 CA 1515-9 - SP 15.
  • Page 6: General Safety Instructions

    User's Manual ‘SP’ Models based upon the CA Series 1. General Safety Instructions CAUTION Risk of electric shock! Do not open the units! Warning: To avoid electric shock hazard, do not expose this appliance to rain or moisture. The enclosures may only be opened by qualified personnel! Do not install devices in any of the following places: −...
  • Page 7: Mounting The Speakers

    User’s Manual ‘SP’ Models based upon the CA Series Maintenance and technical service The user should not perform any maintenance work on the equipment other than that which is described in this manual. Repairs should be executed by a qualified service technician only.
  • Page 8: Introduction Sp Loudspeakers

    User's Manual ‘SP’ Models based upon the CA Series 2. Introduction SP Loudspeakers ‘SP’ denotes a new option for selected models in the K&F range of loudspeakers. Based on selected K&F speaker systems, the ‘SP’ models are equipped with state-of- the-art integrated driver circuits and Class D power amplifier technology.
  • Page 9 (EQ), etc. The following K&F ‘SP’ speakers are available: Full-range systems: CA 1001 - SP, CA 1201 - SP, CA1215-6 - SP, CA 1215-9 - SP CA 1515-6 - SP, CA 1515-9 - SP...
  • Page 10: Connectors, Controls Und Displays

    User's Manual ‘SP’ Models based upon the CA Series 3. Connectors, Controls und Displays 1) LINE IN and LINE OUT (+6 dB) Electronically balanced input and output connectors. Use the XLR female connector (marked ‘IN’) as input. The parallel-wired XLR male connector (‘OUT’) is for connec- tion to further ‘SP’...
  • Page 11 User’s Manual ‘SP’ Models based upon the CA Series 4) GAIN CONTROL (± 6 dB) a) The gain control can be used to adjust the input level of the amplifier module by ± 6dB. It serves to balance the volume levels of the various systems. In or- der to avoid overloading the input circuit or mixer’s output circuit, it should normally be set in the case of K&F full-range systems at 0 dB (centre notch setting).
  • Page 12 User's Manual ‘SP’ Models based upon the CA Series 6) LED POWER ON (GREEN) and LIMIT / PROTECT (RED) The LED is dual-purpose: a) When the LED is green, the speaker is connected to the supply voltage and ready for operation b) The LED will turn red if…...
  • Page 13: Power Cord

    User’s Manual ‘SP’ Models based upon the CA Series 7) AC MAINS ‘IN’ Connect this PowerCon socket using the mains cable supplied to a max. 16 A fused mains socket, paying particular attention to the stated mains voltage! Connection to an incorrect mains voltage can result in irreparable damage! Important 8) AC MAINS ‘OUT’...
  • Page 14: Instructions For Suspending The Speakers

    User's Manual ‘SP’ Models based upon the CA Series 5. Instructions for Suspending the Speakers Only trained personnel may suspend speaker systems. Pay attention the accompanying safety and assembly instructions carefully as well as the required safety factors. Please follow the corresponding national safety regulations.
  • Page 15: Using The 'Allsafe Jungfalk' Flying Points

    User’s Manual ‘SP’ Models based upon the CA Series Us Us Using the ‘allsafe JUNGFALK’ Flying Points ing the ‘allsafe JUNGFALK’ Flying Points ing the ‘allsafe JUNGFALK’ Flying Points ing the ‘allsafe JUNGFALK’ Flying Points Single Stud Fitting ‘allsafe JUNGFALK’ flying point Used as fastener to the ‘allsafe Receptacle for special fasteners.
  • Page 16: Coverage Patterns Of The Sp Speakers

    DEFINITION: Horn not rotated Horn rotated Standing speaker: Model CA 1001 - SP 85° h x 55° v 55° h x 85° v CA 1201 - SP 90° h x 60° v 60° h x 90° v CA 1215-6 - SP 65°...
  • Page 17: Mounting Instructions For Speakers

    User’s Manual ‘SP’ Models based upon the CA Series 7. Mounting Instructions for Speakers Mount the speakers securely. To avoid injury or damage, always be sure to mount the speakers securely so that they do not fall. Speakers, which are stacked, must be secured with securing straps.
  • Page 18: Arrayed Speaker Systems (Cluster)

    User's Manual ‘SP’ Models based upon the CA Series Arrayed Speaker Systems (Cluster) If the loudspeakers are operated through the optional K&F C2 System Controller, we recommend to turn on the 'Top Low Cut' switch for clustered operation. Thus the fre- quency response for this application can be optimised (see also K&F C2 user's manual).
  • Page 19: With Rotated Horn

    User’s Manual ‘SP’ Models based upon the CA Series 7.2.2 With rotated Horn Winkel 2 Winkel 3 Horn rotated Standing speaker A smaller angle 3 results in a smaller Winkel 1 vertical coverage angle but increases the sound power level. Combination Angle 1 Angle 2...
  • Page 20: Wiring

    User's Manual ‘SP’ Models based upon the CA Series 8. Wiring Before connecting your SP system as shown in chapter 9, be sure to switch off all con- nected appliances and turn down all level controls. − We recommend the use of high-quality cables provided by KLING & FREITAG. −...
  • Page 21: Connecting The Power Connectors To The Connecting Terminal

    User’s Manual ‘SP’ Models based upon the CA Series Connecting the Power Connectors to the Connecting Terminal Only use the supplied power cable and connect it to a mains outlet with a 16 A fuse. Warning See instructions in chapter 4 ‘Power Cord’ on page 13. 9.
  • Page 22: Full-Range Mode With Subwoofer

    User's Manual ‘SP’ Models based upon the CA Series 9.1.2 Full-Range Mode with Subwoofer You can link the input signal (for example from the mixer) from one loudspeaker to another. It makes no difference whether the input signal reaches the bass speaker first and is then transmitted to the mid-high speaker or the other way around.
  • Page 23: Operations With C2 Controller

    User’s Manual ‘SP’ Models based upon the CA Series Operations with C2 Controller The frequency range of the SP speakers with filters switched off (FILTERS 'OFF') is 100% identical to the frequency range of the corresponding K&F speakers without SP module (in the case of subwoofers the models without XO).
  • Page 24: 2-Way Active Mode With K&F Controller C2

    User's Manual ‘SP’ Models based upon the CA Series 9.2.2 2-Way Active Mode with K&F Controller C2 The switch ‘FILTERS’ on the SP speaker must be at ‘OFF’ in this mode. The ‘Sense’ cables on the C2 Controller do not need to be connected as the SP speakers have their own limiters! The countersunk switch ‘Full-Range Mode’...
  • Page 25: Maximum Configuration

    User’s Manual ‘SP’ Models based upon the CA Series Maximum Configuration It is possible to use a large number of SP speakers in parallel simultaneously, however, this number is limited according to the permitted minimum load impedance of the sig- nal source (e.g.
  • Page 26: Operating The Speakers

    User's Manual ‘SP’ Models based upon the CA Series 10. Operating the Speakers − Switch off all equipment and make sure that the SP speakers are not connected to a power source. − Connect your SP systems in accordance with the preceding connection diagrams. Use only mains cables, which comply with your national safety regulations.
  • Page 27: Block Diagram Of The Sp Full-Range Speaker

    User’s Manual ‘SP’ Models based upon the CA Series 12. Block Diagram of the SP Full-Range Speaker KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 27 of 54...
  • Page 28: Technical Specifications

    User's Manual ‘SP’ Models based upon the CA Series 13. Technical Specifications 13.1 CA 1001 - SP Loudspeaker Design 2-way full-range system with integrated driver and power amplifier technology, bass reflex tuning Frequency range -10 dB 53 Hz - 20 kHz (‘FILTERS OFF’) Frequency range ±3 dB...
  • Page 29: Ca 1201 - Sp

    User’s Manual ‘SP’ Models based upon the CA Series 13.2 CA 1201 - SP Loudspeaker Design 2-way full-range system with integrated driver and power amplifier technology, bass reflex tuning Frequency range -10 dB 54 Hz - 19 kHz ('FILTERS OFF') Frequency range ±3 dB 65 Hz - 18 kHz ('FILTERS ON' and 'FILTERS OFF') Nominal coverage angle...
  • Page 30: Ca 1215-6 - Sp

    User's Manual ‘SP’ Models based upon the CA Series 13.3 CA 1215-6 - SP Loudspeaker Design 2-way full-range system with integrated driver and power amplifier technology, bass reflex tuning Frequency range -10 dB 62 Hz - 22 kHz ('FILTERS OFF') Frequency range ±...
  • Page 31: Ca 1215-9 - Sp

    User’s Manual ‘SP’ Models based upon the CA Series 13.4 CA 1215-9 - SP Loudspeaker Design 2-way full-range system with integrated driver and power amplifier technology, bass reflex tuning Frequency range -10 dB 58 Hz - 22 kHz ('FILTERS OFF') Frequency range ±...
  • Page 32: Ca 1515-6 - Sp

    User's Manual ‘SP’ Models based upon the CA Series 13.5 CA 1515-6 - SP Loudspeaker Design 2-way full-range system with integrated driver and power amplifier technology, bass reflex tuning Frequency range -10 dB 47 Hz - 22 kHz ('FILTERS OFF') Frequency range ±...
  • Page 33: Ca 1515-9 - Sp

    User’s Manual ‘SP’ Models based upon the CA Series 13.6 CA 1515-9 - SP Loudspeaker Design 2-way full-range system with integrated driver and power amplifier technology, bass reflex tuning Frequency range -10 dB 48 Hz - 22 kHz ('FILTERS OFF') Frequency range ±...
  • Page 34: Measuring Charts

    User's Manual ‘SP’ Models based upon the CA Series 14. Measuring Charts 14.1 CA 1001 - SP Frequency response ‘on axis’ Filters 'OFF' Filters 'ON' 1000 10000 20000 Frequency (Hz) Frequency response ‘on axis’ with K&F Controller C2 (Filters ‘OFF’)
  • Page 35 User’s Manual ‘SP’ Models based upon the CA Series Vertical frequency response ‘off axis down’ 0° 10° 20° 30° 40° 1000 10000 20000 Frequency (Hz) Beamwidth Horizontal Vertical 1000 10000 20000 Frequency (Hz) Q-Index 1000 10000 20000 Frequency (Hz) KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 35 of 54...
  • Page 36: Ca 1201 - Sp

    User's Manual ‘SP’ Models based upon the CA Series 14.2 CA 1201 - SP Frequency response ‘on axis’ Filters 'OFF' Filters 'ON' 1000 10000 20000 Frequency (Hz) Frequency response ‘on axis’ with K&F Controller C2 (Filters ‘OFF’) Fullrange 2-Way TopLowCut / Fullrange TopLowCut / 2-Way High Boost 1000...
  • Page 37 User’s Manual ‘SP’ Models based upon the CA Series Vertical frequency response ‘off axis down’ 0° 10° 20° 30° 40° 1000 10000 20000 Frequency (Hz) Beamwidth Horizontal Vertical 1000 10000 20000 Frequency (Hz) Q-Index 1000 10000 20000 Frequency (Hz) KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 37 of 54...
  • Page 38: Ca 1215-6 - Sp

    User's Manual ‘SP’ Models based upon the CA Series 14.3 CA 1215-6 - SP Frequency response ‘on axis’ Filters 'OFF' Filters 'ON' 1000 10000 20000 Frequency (Hz) Frequency response ‘on axis’ with K&F Controller C2 (Filters ‘OFF’) Fullrange 2-Weg TopLowCut / Fullrange TopLowCut / 2-Weg High Boost 1000...
  • Page 39 User’s Manual ‘SP’ Models based upon the CA Series Vertical frequency response ‘off axis down’ 0° 10° 20° 30° 40° 1000 10000 20000 Frequency (Hz) Beamwidth Horizontal Vertical 1000 10000 20000 Frequency (Hz) Q-Index 1000 10000 20000 Frequency (Hz) KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 39 of 54...
  • Page 40: Ca 1215-9 - Sp

    User's Manual ‘SP’ Models based upon the CA Series 14.4 CA 1215-9 - SP Frequency response ‘on axis’ Filters 'OFF' Filters 'ON' 1000 10000 20000 Frequency(Hz) Frequency response ‘on axis’ with K&F Controller C2 (Filters ‘OFF’) Fullrange 2-Weg TopLowCut / Fullrange TopLowCut / 2-Weg High Boost 1000...
  • Page 41 User’s Manual ‘SP’ Models based upon the CA Series Vertical frequency response ‘off axis down’ 0° 10° 20° 30° 40° 1000 10000 20000 Frequency (Hz) Beamwidth Horizontal Vertical 1000 10000 20000 Frequency (Hz) Q-Index 1000 10000 20000 Frequency (Hz) KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 41 of 54...
  • Page 42: Ca 1515-6 - Sp

    User's Manual ‘SP’ Models based upon the CA Series 14.5 CA 1515-6 - SP Frequency response ‘on axis’ Filters 'OFF' Filters 'ON' 1000 10000 20000 Frequency(Hz) Frequency response ‘on axis’ with K&F Controller C2 (Filters ‘OFF’) Fullrange 2-Weg TopLowCut / Fullrange TopLowCut / 2-Weg High Boost 1000...
  • Page 43 User’s Manual ‘SP’ Models based upon the CA Series Vertical frequency response ‘off axis down’ 0° 10° 20° 30° 40° 1000 10000 20000 Frequency (Hz) Beamwidth Horizontal Vertikal 1000 10000 20000 Frequency (Hz) Q-Index 1000 10000 20000 Frequency (Hz) KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 43 of 54...
  • Page 44: Ca 1515-9 - Sp

    User's Manual ‘SP’ Models based upon the CA Series 14.6 CA 1515-9 - SP Frequency response ‘on axis’ Filters 'OFF' Filters 'ON' 1000 10000 20000 Frequency(Hz) Frequency response ‘on axis’ with K&F Controller C2 (Filters ‘OFF’) Fullrange 2-Weg TopLowCut / Fullrange TopLowCut / 2-Weg High Boost 1000...
  • Page 45 User’s Manual ‘SP’ Models based upon the CA Series Vertical frequency response ‘off axis down’ 0° 10° 20° 30° 40° 1000 10000 20000 Frequency (Hz) Beamwidth Horizontal Vertikal 1000 10000 20000 Frequency (Hz) Q-Index 1000 10000 20000 Frequency (Hz) KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 45 of 54...
  • Page 46: Dimensions

    User's Manual ‘SP’ Models based upon the CA Series 15. Dimensions 15.1 CA 1001 - SP Gewindeeinsatz M8 für Stativadapter & TV-Zapfenadapter Flugpunkt Gewindeeinsatz M10 99 mm 115 mm Flugpunkt [3.898"] [4.528"] Gewindeeinsatz M10 Flugpunkt Gewindeeinsatz M10 313 mm 156 mm 307 mm [12.323"]...
  • Page 47: Accessories

    User’s Manual ‘SP’ Models based upon the CA Series 15.3 CA 1515-6/-9 -- - SP Flugpunkte ANCRA Jungfalk 120030-31 Kunststoff- Gleitf üße 433.6 mm 411.3 mm 212.3 mm [17.073 inch] [16.195 inch] [8.358 inch] Hochst änder- buchse 73° K&M 19656 48°...
  • Page 48 User's Manual ‘SP’ Models based upon the CA Series Adjustable Speaker Mount CA 1201/CA1215 Cradle 1201/CA1215 Adjustable Speaker Mount CA 1515 Cradle 1515 Multi Cradle CA 1201/CA1215 Wall Mount, Multi Cradle CA 1515 tiltable, max. 50 kg Schwenkbügel Stativadapter Distanzrohr Distance rod &...
  • Page 49: Regulations For Disposal

    User’s Manual ‘SP’ Models based upon the CA Series 17. Regulations for Disposal 17.1 Germany: It is not allowed to dispose of used electrical equipment as domestic waste. But please do not dispose of them at official collecting points for recycling either! All Kling &...
  • Page 50: Declaration Of Conformity And International Certificates

    Kind of equipment: Loudspeaker systems with integrated amplifier(s) Type-designation: CA 1001 - SP, CA 1201 - SP, CA 1215-6 - SP, CA 1215-9 - SP, CA 1515-6 - SP, CA 1515-9 - SP,...
  • Page 51: Emv Certificate Guideline 89 / 336 / Ewg

    User’s Manual ‘SP’ Models based upon the CA Series 18.2 EMV Certificate Guideline 89 / 336 / EWG EMV Certificate Guideline 89 / 336 / EWG EMV Certificate Guideline 89 / 336 / EWG EMV Certificate Guideline 89 / 336 / EWG KLING &...
  • Page 52 User's Manual ‘SP’ Models based upon the CA Series KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 52 of 54...
  • Page 53: Tüv Certificate For The Usa And Canada (Ul 6500)

    User’s Manual ‘SP’ Models based upon the CA Series 18.3 TÜV Certificate for the USA and Canada (UL 6500) TÜV Certificate for the USA and Canada (UL 6500) TÜV Certificate for the USA and Canada (UL 6500) TÜV Certificate for the USA and Canada (UL 6500) KLING &...
  • Page 54 User's Manual ‘SP’ Models based upon the CA Series KLING & FREITAG GMBH ©2003 - 2006 Version 6.1, 19.06.2006 Page 54 of 54...