User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Contents Chapter Page General Safety Instructions Introduction SP Loudspeakers Connectors, Controls und Displays Power Cord Rigging Instructions for Line 212 Systems 5.1 Vertical Suspension 5.2 Horizontal Suspension Using the ‘allsafe JUNGFALK’ Flying Points Using the Rear Mounted ‘allsafe JUNGFALK’...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 1. General Safety Instructions CAUTION Risk of electric shock! Do not open the units! Warning: To avoid electric shock hazard, do not expose this appliance to rain or moisture. The enclosures may only be...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Maintenance and technical service The user should not perform any maintenance work on the equipment other than that which is described in this manual. Repairs should be executed by a qualified service technician only.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 2. Introduction SP Loudspeakers ‘SP’ denotes the ‘Self Powered’ product line in the K&F range of loudspeakers. Based on selected K&F speaker systems, the ‘SP’ models are equipped with state-of-the-art integrated driver circuits and Class D power amplifier technology.
Page 8
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Modes of Operation − Operations without external controller: with activated filters (FILTERS ‘ON’), all K&F models in the ‘SP Series’ are combina- ble with one another by simply linking the signal from one speaker to the next.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 3. Connectors, Controls und Displays 1) LINE IN and LINE OUT (+6 dB) Electronically balanced input and output connectors. Use the XLR female connector (marked ‘IN’) as input. The parallel-wired XLR male connector (‘OUT’) is for connec- tion to further ‘SP’...
Page 10
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 4) GAIN CONTROL (± 6 dB) a) The gain control can be used to adjust the input level of the amplifier module by ± 6dB. It serves to balance the volume levels of the various systems. In or- der to avoid overloading the input circuit or mixer’s output circuit, it should...
Page 11
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 5) FILTERS ON / OFF (High Pass / Low Pass / Equalizer) This switch turns the filter in the SP module on (‘ON’), or off (‘OFF’). a) The switch should always be in the ‘ON’ position when the speakers are being driven without K&F System Controller.
Page 12
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP The LED stays permanently red, if… …the protection circuitry of the integrated power amplifier cuts in and as a result, no further signal reaches the speaker (Protect Mode). The protection circuitry switches off the integrated power amplifier,…...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 4. Power Cord In Germany, a pre-constructed ready for use power cord is included in the delivery. For deliveries to foreign countries, a pre-constructed power cord incl. PowerCon plug is included.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 5. Rigging Instructions for Line 212 Systems The speakers may only be mounted by trained specialised per r r r sonnel with proof The speakers may only be mounted by trained specialised pe...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 5.2 Horizontal Suspension If a speaker unit consisting of several connected systems is to be flown and aligned, then the individual speakers must be attached to one another before connecting them to the ‘allsafe JUNGFALK’...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 6. Using the ‘allsafe JUNGFALK’ Flying Points Single Stud Fitting ‘allsafe JUNGFALK’ Flying Point Used as fastener to the ‘allsafe Receptacle for special fasteners. JUNGFALK’ Flying Point. Take the single stud fitting in one ...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 7. Using the Rear Mounted ‘allsafe JUNGFALK’ Flying Track The ‘allsafe JUNGFALK’ flying track can be used for fixing and adjust- ing the speaker systems. The ‘allsafe JUNGFALK’ flying track can only support weights...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 7.2 Mounting the Double Stud Fitting Double Stud Fitting ‘allsafe JUNGFALK’ Flying Track Used as fastener to the ‘allsafe Receptacle for the double stud fit- JUNGFALK’ Flying Point and the ting.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 8. Coverage Pattern of the Line 212 -- - SP Systems The Line 212 can be operated in a vertical or horizontal position. The coverage pattern of the speaker can be adapted to special needs by a 90° rotatable horn.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 9. Mounting Instructions for Speakers Mount the speakers securely. To avoid injury or damage, always be sure to mount the speakers securely so that they do not fall. Speakers, which are stacked, must be secured with securing straps.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 9.2 Arrayed Speaker Systems (Cluster) If the loudspeakers are operated through an optional K&F System Controller, we rec- ommend turning on the 'Top Low Cut' filter for clustered operation. Thus the fre- quency response for this application can be optimised (see user’s manual of the control-...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 9.3 LINE 212 Systems on Top of SW 215E In addition to the stacking foot grooves for stacks of idenctical enclosures, the subwoofer SW 215E also has stacking foot grooves for the Line 212 System.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 10. Wiring Before connecting your SP system, be sure to switch off all connected appliances and turn down all level controls. We recommend the use of high-quality cables provided by KLING & FREITAG.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 10.2 Connecting the Power Connectors to the Connecting Terminal Only use the supplied power cable and connect it to a mains outlet with a 16 A fuse. Warning See instructions in chapter 4‚ ‘Power Cord’ on page 13.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 11. Configurations and Connecting Diagrams 11.1 Operating the Systems without K&F System Controller The full-range system can be used alone or in conjunction with an SP subwoofer. The subwoofer has an integrated filter for use in this mode, which limits the bandwidth.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 11.1.2 Full Range Mode with Subwoofer You can link the input signal (for example from the mixer) from one loudspeaker to another. It makes no difference whether the input signal reaches the bass speaker first and is then transmitted to the mid-high speaker or the other way around.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 11.2 Operating the Systems with K&F System Controller For optimal performance with an extended functional range we recommend using a K&F system controller. Instructions for use, connecting diagrams and detailed descrip- tions of the latest controller models ‘CD 24’...
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 12. Operating the Speakers − Switch off all equipment and make sure that the SP speakers are not connected to a power source. Connect your SP systems in accordance with the preceding connection diagrams.
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 19. Regulations for Disposal 19.1 Germany It is not allowed to dispose of used electrical equipment as domestic waste. But please do not dispose of them at official collecting points for recycling either! All Kling &...
Page 42
User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Das v erk nüpfte Bild k ann nicht angezeigt werden. Möglicherweise wurde die Datei v erschoben, umbenannt oder gelöscht. Stellen Sie sicher, dass die Verk nüpfung auf die k orrek te Datei und den k orrek ten Speicherort zeigt.