7013-XXX
Base Sensor Test
These tests allow you to verify the correct functioning of the front door, input, and output sensors.
1.
Select Base Sensor Test from Diag Menu, and press Select (
2.
Select the sensor you want to test, and press Select (
The following test are available:
Sensor
Input
Front door
Narrow media
Fuser exit
Manual feed
To exit the test, press
Printer Setup
Defaults
US/Non-US defaults changes whether the printer uses the US factory defaults or the non-US factory defaults.
The settings affected include paper size, envelope size, PCL symbol set, code pages, and units of measure.
Warning: Changing this setting resets the printer to factory defaults, and data may be lost. It cannot be undone.
Page Counts
You can view, but not change any of the three counts displayed under PAGE COUNTS.
To view the Prt Color Pg Count, the Prt Mono Pg Count, or the Perm Page Count:
1.
Select PRINTER SETUP from DIAGNOSTICS, and press Select (
2.
Select PAGE COUNTS, and press Select (
3.
Select the page count you wish to view:
•
Prt Color Pg Count
•
Prt Mono Pg Count
•
Perm Page Count
4.
Press Select (
The value of the page count appears.
Press Back (
3-12
Service Manual
Value
Value opened/value
closed
Value opened/value
closed
Narrow and wide
Value opened/ value
closed
Value opened/value
closed
or
.
).
)
to return to PRINTER SETUP.
).
).
How to test
Remove the cartridge, and toggle the narrow media
actuator manually.
Open and close the front door.
Toggle the narrow media actuator manually.
Open the front door. Activate the fuser exit flag. The
sensor should change state.
Toggle the actuator.
).
).