Water Filter Installation

(Side-by-Side with Dispenser)
24
Locate water filter door. The door is located under
the adjustable cold zone handle.
26
Insert filter cartridge into circular opening
in filter housing. Rotate clockwise gently until
filter stops.Close water filter door.
64
25
1
Push upper left corner of door to release latch
and pull door downward.
27
Note: Allow 1-2 minute delay in water
dispersal to allow internal water tank to fill.
Flush air from the system by running water through
the dispenser continuously for 3 minutes.
Water Filter System Specification and
Performance Data Sheet
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration of less
than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety
factors built-in for unmetered usage for health claims only.)
Standard No. 42: Aesthetic Effects
Parameter
USEPA
Influent
Influent
McL
Average
Challenge
Concentrations
Chlorine
1.88 mg/L
2.0 mg/L + 10%
T&O
Particulates**
5,700,000 #/mL
at least
10,000 particles/mL
Standard No. 53: Health Effects
Parameter
USEPA
Influent
Influent
McL
Average
Challenge
Concentrations
Turbidity
1 NTU***
10.73 NTU*** 11 + 1 NTU
Cysts
99.95%
Reduction
200,000 #/L
min. 50,000/L
10 7 & 10 8 fibers/L
99% Reduction
155 MF/L
Asbestos
fibers>10micrometers
0.015 mg/L
0.153 mg/L
0.15mg/L + 10%
Lead at pH 6.5
0.015 mg/L
0.150 mg/L
0.15mg/L + 10%
Lead at pH 8.5
0.002 mg/L
0.006 mg/L
.006mg/L + -10%
Mercury at pH 6.5
0.002mg/L
0.006 mg/L
.006mg/L + -10%
Mercury at pH 8.5
0.0002 mg/L
0.002 mg/L
.002mg/L + 10%
Lindane
Atrazine
0.003 mg/L
0.00873 mg/L .009mg/L + 10%
Toxaphene
0.003 mg/L
0.015 mg/L
.015mg/L + 10%
*Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp of 68
**Measurement in particles/mL. Particles used were 0.5 - 1 microns
***NTU = Nephelometric Turbidity units
Operating Specifications
Capacity:
Certified for up to 750 gallons (2,838 L); up to nine months
Pressure Requirement:
20 - 120 psi (2.8 - 8.2 bar)
Temperature:
33-100
o
F (0.6 - 38
Flow rate:
0.78 gpm (2.9 l/min.)
Check for compliance with the state and local laws and regulations.
Note: While the testing was performed under standard laboratory conditions, actual performance may vary.
Must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Installation instructions, parts and service availability, and standard warranty are included with the product when
shipped. This drinking water system must be maintained according to manufacturer's instruction, including
replacement of filter cartridges.
Manufactured by: Cuno, a 3M company
1000 Apollo Road
Eagan, MN 55121
(651) 450-4913
Effluent
%Reduction
Average
Maximum
Average
Minimum
<0.05mg/L 0.06 mg/L
>97.26%
96.84%
29.83#/mL
140 #/mL
99.98%
99.91%
Effluent
%Reduction
Average
Maximum
Average Minimum Reduction
0.36 NTU
.049 NTU
97.09%
95.20%
<1
<1
>99.99% >99.99%
<1
<1
>99.99% >99.99%
<.001
<.001
>99.35% >99.35%
<.001
<.001
>99.35% 97.35%
0.00026
0.0005
98.72%
90.91%
0.0008
0.0015
98.72%
75.93%
0.000025
0.00007
98.72%
96.50%
<.002 mg/L <.002 mg/L
76.99%
75.31%
<0.001
<0.001
92.97%
91.67%
o
+ 5
o
F (20
o
+ 3
o
C)
o
C)
System tested and certified by NSF International
against Standard 42 for the reduction of chlorine taste
and odor, particulate Class I and Standard 53 for the
reduction of Lead, Lindane, Atrazine, Mercury,
Toxaphene, Cyst, Turbidity, and Asbestos.
65
Min. Req.
Reduction
> 50%
> 85%
Min. Req.
0.5 NTU
>99.95%
99%
0.010 mg/L
0.010 mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.003 mg/L
0.003mg/L

Advertisement