Connection Of Waterway System - Gree GRS-CQ16Pd/NaB-K Owner's Manual

Air-to-water heat pump
Table of Contents

Advertisement

Description
Hot water outlet of water tank
Circulating water inlet/outlet of water tank
Cooling water inlet of water tank
Pipe joint

18.3 Connection of waterway system

(1) If connection between water tank and indoor unit should be through the wall, drill a holeφ70
for pass of circulating water pipe. It is unnecessary if the hole is not needed.
(2) Preparation of pipelines: Circulating water outlet/inlet pipe must be hot water pipe, PPR
pipe with nominal out diameter of dn25 and S2.5 series (wall thickness of 4.2mm) being
recommended. Cooling water inlet pipe and hot water outlet pipe of water tank should
also be hot water pipe, PPR pipe with nominal out diameter of dn20 and S2.5 series (wall
thickness of 3.4mm) being recommended. If other insulated pipes are adopted, refer to the
above dimensions for out diameter and wall thickness.
(3) Installation of circulating water inlet/outlet pipes: Connect the water inlet of unit with
circulating outlet of water tank and water outlet of unit with circulating inlet of water tank.
(4) Installation of water inlet/outlet pipes of water tank: Safety check valve (→ on the valve body
points at water tank), filter and cut-off valve must be installed for water inlet pipe according to
the installation sketch of unit. At least a cut-off valve is needed for the water outlet pipe.
(5) Installation of blow-off pipe at the bottom of water tank: Connect a piece of PPR pipe with
drainage outlet to floor drain. A cut-off valve must be installed in the middle of the drainage
pipe and at the place where it is easy to be operated by the users.
(6) After connection of all waterway pipelines, perform leakage test firstly (refer to debugging
of the unit). After that, bind up the water pipes, water temp sensor and wires with wrapping
tapes attached with the unit.
(7) Refer to Installation Sketch of Unit for details.
Indoor Unit
Other Thermal sensor (less than 5 meters)
Power cord of booster heater
Joints Dimension
Water Tank
Temp Sensor 1
Safety check
valve
temp sensor 2
Cool Water
Inlet
Blow-off Outlet
Cut-off Valve
26
Air-to-water Heat Pump
Joint pipe thread
1/2"Female BSP
3/4"Female BSP
1/2"Female BSP
3/4"Female BSP
Hot water output
Other
Thermal
System
Filter
Tap water

Advertisement

Table of Contents
loading