Electrical Connection - Bosch DHZ 2100 Operating And Installation Instructions

Table of Contents

Advertisement

Prior to installation
Extractor hoods with 150 mm Ø air
outlet:
150 mm l extraction pipe
❑ Screw the reducing connector (see
optional accessories on the last page)
onto the air outlet.
❑ Attach the extraction pipe to the redu-
cing connector.
150 mm l extraction pipe
❑ Attach the exhaust-air pipe directly to
the air outlet..
If a one-way flap has been fitted, con-
duct a performance test.
Extractor hoods with rectangular air
outlet:
❑ Screw the enclosed
air-pipe connector
over the air outlet.
Recirculated air mode
❑ The air cleaned by
an additional
activated carbon
filter is conveyed
back into the
room.
❑ In recirculated air
mode the exhaust
opening must be
protected by a
grille (see optional
accessories on the last page) in order to
prevent a mechanical or electrical
hazard.
8

Electrical connection

The extractor hood must be connected to
a correctly installed earthed socket only.
Attach the earthed socket as close to the
appliance as possible and in an accessible
position. If the earthed socket is no longer
accessible following installation of the
extractor hood, a disconnector must be
provided on the installation side. Dis-
connectors are switches with a contact
opening of more than 3 mm and all-pole
disconnection. LS switches and contactors
are regarded as disconnectors.
The appliance must be isolated before
repairs are carried out.
Repairs may be carried out by authorised
technicians only.
If the connection cable of this appliance
is damaged, it must be replaced by the
manufacturer, his customer service or a
similarly qualified person in order to prevent
a hazardous situation.
Improper repairs may put the user at
considerable risk.
Length of connection cable: 1.20 m.
Electrical specifications:
The electrical specifications can be found
on the rating plate inside the appliance
when the filter frame has been removed.
Do not place hand in the air outlet.
This appliance complies with the EC radio
interference suppression regulations.
Installation
The extractor hood is particularly suitable
for installation in a flue or chimney.
To ensure optimum extraction perfor-
mance
(especially important for kitchen island solu-
tions):
❑ Install the extractor hood as high as
possible within the structure
❑ The structure must cover the entire
cooking area.
The following cutouts must be made for
the installation depending on the model:
Extractor hood with rocker switch, 53 cm
wide, 1-motor:
16
248
248
120
100
160
12
530
75
280
47 75
256