11.11.4 SETTINGS
CONTROL USING TWO REMOTE CONTROLLERS
If both the infrared remote controller and the optional wired remote controller are being used together, either
remote controller can be used to operate the indoor units. (The indoor unit can be used to operated with the last
switch pressed having priority.)
Up to 2 optional wired remote controllers can be connected and used.
1 REMOTE CONTROLLER GROUP CONTROL
When using group control, up to a maximum of 16 indoor units can be connected. (Do not mix heat pump units
and cooling only units.)
For details on how to set the address (A/C No.) for group control, refer to the "Setting for 1 remote controller
group control" section in the installation instructions provided with the indoor unit.
LOCAL SETTING
Press the SET switch
Use the
switches TEMP to choose the "Mode No."
Use the
switches TIMER to choose the "Setting value".
Press the SET switch
The setting details are displayed for approximately 4 seconds and then
it exits the local setting mode.
If no operation is performed, the "Local setting mode" clears after 30 seconds.
Model No.
00
Indoor unit address setting
02
Low sound at night
06
Outdoor unit address setting
Note: 1. The default setting at shipment is "000".
SETTING INDOOR UNIT ADDRESS
Setting and clearing the indoor unit address (Central control address) can be performed.
It is possible to set the address value from "001" to "200". Setting the address to "000" clears it.
Set the mode number to "00" and choose a setting value from "000" to "200" according to the local setting
procedure.
Indoor unit No. 1
Wired
control
(optional)
DIP
switch
Printed
Terminal
circuit
block
board
Infrared receiver
2 to operate the "Local setting mode".
1 to check the setting details.
Item
Indoor unit No. 2
DIP
switch
Printed
Terminal
circuit
block
board
Setting Value
000
Clear address
Set address
001 ~ 200
"001" to "200"
000
Not set (Clear)
001
Low sound level 1
002
Low sound level 2
003
Low sound level 3
000
Clear address
Set address
001 ~ 199
"001" to "199"
140
Indoor unit No. 3
DIP
switch
Printed
Terminal
circuit
block
board
Setting Remarks