Lg air conditioner owner's manual

Advertisement

Air Conditioner

OWNER'S MANUAL
MODELS:
LG-BKE 7630 NS G
LG-BKE 7630 NS M
LG-BKE 7630 NS A
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
Prior to installation, this air-
conditioning unit must be
submitted for approval by the
utility service which provides
electricity (EN 61000-2,
EN 61000-3 Norm).

Advertisement

Table of Contents
loading

Summary of Contents for Beko LG-BKE 7630 NS G, LG-BKE 7630 NS M, LG-BKE 7630 NS A

  • Page 1: Air Conditioner

    Air Conditioner OWNER'S MANUAL MODELS: LG-BKE 7630 NS G LG-BKE 7630 NS M LG-BKE 7630 NS A IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. • Please retain this owner's manual for future reference after reading it thoroughly.
  • Page 2: Table Of Contents

    Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips.
  • Page 3: Safety Precautions

    Safety Precautions To prevent the injury of the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
  • Page 4 Take care so that the power cord may not be pulled during operation. • Otherwise, it may cause a fire or electrical shock. 4 Room Air Conditioner Do not keep or use flammable gases or combustibles near the air conditioner.
  • Page 5 Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands. • Otherwise, it may cause a fire or electrical shock. Do not allow water to run into electrical parts. •...
  • Page 6 Always inspect gas leakage after the installation and repair of product. • Otherwise, it may cause the failure of product. 6 Room Air Conditioner Take care so that children may not step on the outdoor unit. • Otherwise, children may be seriously injured due to falling down.
  • Page 7 Operation Avoid excessive cooling and perform ventilation sometimes. • Otherwise, it may do harm to your health. Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles. • Otherwise, it may damage your properties.
  • Page 8: Prior To Operation

    Cleaning and Maintenance 1. Do not touch the metal parts of the unit when removing the filter. Injury can occur. 2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to electric shock.
  • Page 9: Introduction

    Introduction Symbols used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air conditioner. This symbol indicates special notes. NOTICE Features WARNING: This appliance should be installed in accordance with national wiring regulations.
  • Page 10: Electrical Safety

    WARNING: If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.
  • Page 11 Temporary Use of an Adapter We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a UL-listed adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection. To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal.
  • Page 12: Operating Instructions

    (Cooling model only) Nano Plasma : The function illustrates its dynamic mode by using a multiple lighting system. 12 Room Air Conditioner • To operate the room air conditioner, aim the remote controller at the signal receptor. Operation indicating lamps...
  • Page 13 Remote Control Operations The controls will look like the following. Controls Signal transmitter CANCEL AUTO CLEAN Operation Mode Cooling Operation Auto Operation or Auto Changeover Healthy Dehumidification Operation Heating Operation • Cooling Model( ), Heat Pump Model( 1. START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again.
  • Page 14: Cooling Operation

    For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic. 14 Room Air Conditioner Press the Start/Stop button.
  • Page 15: Auto Operation (Cooling Model Only)

    Auto operation (Cooling model only) During Auto Operation You cannot control the indoor fan speed. It has already been set by the Fuzzy rule. If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating mode to cooling mode, it must be done by manually resetting.
  • Page 16 Auto changeover operation(Heat pump model only) During Auto changeover Operation The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room temperature within ±2°C with respect to setting temperature by auto changeover mode.
  • Page 17: Healthy Dehumidification Operation

    Operating Instructions Healthy dehumidification operation During Healthy Dehumidification Operation If you select the dehumidification mode on the operation selection button, the A/C starts to run the dehumidification function. It automatically sets the room temp. and airflow volume to the best condition for dehumidification, based on the sensed current room temp.
  • Page 18 For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic. 18 Room Air Conditioner Press the Start/Stop button.
  • Page 19: Jet Cool Operation

    Jet cool operation NOTICE During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. quickly in a hot summer. In heat pump mode, neuro fuzzy mode, or auto changeover mode however, the JET COOL function is not available.
  • Page 20 In order to return to the normal heating mode from the JET HEAT mode, just press the operation mode selection button, airflow volume selection, temp. setting button or the JET HEAT button again. 20 Room Air Conditioner Press the Start/Stop button.
  • Page 21 NANO PLASMA purification operation(Optional) NANO PLASMA Air Purifying Operation only Press the Start/Stop button. The unit will respond with a beep. Open the door of the remote controller. Press the NANO PLASMA button. Operation will start when the button is pressed and stop when the button is pressed again.
  • Page 22 Operating Instructions 2nd F operation CANCEL AUTO CLEAN 22 Room Air Conditioner Press the Start/Stop button. The unit will respond with a beep. Open the door of the remote control and press the 2nd Function button to operate functions printed in blue unter buttons.
  • Page 23: Sleep Mode

    Check if 2nd F icon is off. Press the Timer Cancel button aiming the remote controller at the signal receptor. (The timer lamp on the air conditioner and the display will go out.) Select one of the following four types of operation.
  • Page 24: Airflow Direction Control

    Dehumidification Operation can be removed. During Auto Clean function, only Start/Stop button, Plasma button and Auto Clean button are available. 24 Room Air Conditioner Press Chaos Swing button and the louvers will swing. Press the button again and the louvers will stop. After 30 minutes, the louvers return to the maximum airflow position automatically.
  • Page 25: Forced Operation

    Forced operation Operation procedures when the remote control can't be used. The operation will be started if the power button is pressed. If you want to stop operation, re-press the button. Cooling Model Operating mode Cooling Indoor FAN Speed High Setting Temperature 22°C Test operation...
  • Page 26: Maintenance And Service

    • Water hotter than 40°C. Could cause deformation and/or discoloration. • Volatile substances Could damage the surfaces of the air conditioner. Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned.
  • Page 27 Cleaning Filter • Recomended use period : About 3 months 1. Lift the front panel, hold it up and pull the Air filter. 2. Remove the Plasma Filter. WARNING: Don't touch the PLASMA Filter within 10 seconds after opening the inlet grille, it may cause electric shock.
  • Page 28 Before calling for service If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer. Air conditioner does not operate 1.
  • Page 29 Troubleshooting The air conditioner may be operating abnormally when: Problem Possible Causes The air conditioner is unplugged. The fuse is blown/circuit breaker is tripped. conditioner Power failure. does not start Airflow is restricted. The thermostat may not be set high enough.

This manual is also suitable for:

Air conditioner

Table of Contents