Service Code Detection System
The generator may have to run for long periods of time with
no operator present. For that reason, the system is equipped
with sensors that automatically shut down the generator
in the event of potentially damaging conditions, such as
low oil pressure, high temperature, over speed, and other
conditions. Refer to Service Code Detection System in the
operator's manual for more detailed information.

Final Installation Considerations

Engine Oil
NOTICE Any attempt to crank or start the engine before it
has been properly serviced with the recommended oil will
result in equipment failure.
• Refer to Maintenance in the operator's manual for oil
fill information.
• Damage to equipment resulting from failure to follow this
instruction will void engine and generator warranty.
The engine is shipped from the factory pre-run and filled
with synthetic oil (API SJ/CF 5W-30). This allows for system
operation in a wide range of temperature and climate
conditions. Before starting the engine, check oil level and
ensure that engine is serviced as described in Maintenance
of the Operator's Manual.
The use of synthetic oil does not alter the required oil
change intervals described in the Operator's Manual.
For operation of temperatures below 30°F (-1°C), the use of
fully synthetic oil (minimum API SJ) of viscosity 5W30 is
required.
Battery
WARNING Battery posts, terminals and related
accessories contain lead and lead compounds, chemicals
known to the State of California to cause cancer and
reproductive harm. Wash hands after handling.
The installer must supply and install rechargeable starting
battery. The starting battery MUST conform to the
specifications shown below in the chart.
Battery
Standard
Specifications
Volts
12 Volt DC
Amps (MIN)
540 CCA (cold
cranking amps)
Construction
Wet lead acid
Terminal Type
Top post type
battery
Dimensions
BCI size 26
(MAX):
Install the battery as described in Servicing the Battery in the
Maintenance section of the Operator's Manual. Always make
sure the NEGATIVE cable is connected last.
WARNING Storage batteries give off explosive
hydrogen gas during recharging.
Slightest spark will ignite hydrogen
and cause explosion, resulting
in death, serious injury and/or
property damage.
Battery electrolyte fluid contains acid and is
extremely caustic.
Contact with battery contents could cause severe
chemical burns.
A battery presents a risk of electrical shock and high short
circuit current.
• DO NOT dispose of battery in a fire. Recycle battery.
• DO NOT allow any open flame, spark, heat, or lit cigarette
during and for several minutes after charging a battery.
• DO NOT open or mutilate the battery.
• Wear protective goggles, rubber apron, rubber boots and
rubber gloves.
• Remove watches, rings, or other metal objects.
• Use tools having insulated handles.
Cold Start
(less than 30°F)
12 Volt DC
630 CCA (cold
cranking amps)
Wet lead acid
Top post type
battery
BCI size 75
31