The Gaseous Fuel System; Assembly/Installation - Briggs & Stratton 040248A Operator's Manual

7kw backup generator
Table of Contents

Advertisement

Available languages

Available languages

The Gaseous Fuel System

The generator unit has been factory set to run on liquefied
petroleum gas.
WARNING Propane is extremely flammable and
explosive, which could cause burns, fire or
explosion resulting in death, serious injury
and/or property damage.
LP gas is heavier than air and will settle in low areas.
The slightest spark could ignite these fuels and cause
an explosion.
DO NOT light a cigarette or smoke.
The generator engine is fitted with a fuel mixer system that
meets the specifications of the California Air Resources
Board for "tamper-proof" dual fuel systems.
• Use clean, dry fuel, free of moisture or any
particulate material. Using fuels outside the following
recommended values may cause performance
problems:
• Commercial grade HD5 LPG is recommended -
minimum fuel energy of 2500 BTU's/ft3 with maximum
propylene content of 5% and butane and heavier gas
content of 2.5% and minimum propane content of
90%.
• See Specifications for required fuel supply pressure.
Fuel Consumption
See the following table for fuel supply requirements at half
and full load for LP vapor.
LP Vapor*
1/2 Load
33
* = LP Vapor is in cubic feet per hour
8

Assembly/Installation

Your generator is ready for use after you assemble the
LP fuel tank housing pad components, make proper fuel
connections, and verify that engine oil is at the proper level.
If you have any problems with the assembly of
your generator, please call the generator helpline at
1‑800‑743‑4115. If calling for assistance, please have
the model, revision, and serial number from the data tag
available. See Generator Controls and Features for data tag
location.
Shipment Contents
The generator is supplied with:
• Generator pre-attached to mounting pad
• LP fuel tank housing tray assembly pre-attached to
• Fuel hose and regulator assembly pre-attached to
• LP fuel tank all-weather cover
• Bag containing LP fuel tank attachment hardware
• Operator's manual
• Oil drain tray
• Touch-up paint
• One spare 15A fuse
You must purchase two filled 20 pound DOT LP fuel tanks
that are equipped with a listed over-filling prevention device
(OPD).
Full Load
56
mounting pad
generator
BRIGGSandSTRATTON.COM