WT4901/WT8901 Siren Battery Test
To determine which siren has a low battery press and hold the test button, located at the front of
the siren, for 5 seconds.
• If the siren sounds for 4 seconds, the batteries are good.
• If the siren doesn't sound, the batteries are low.
WT4901/WT8901 Siren Battery Replacement
• Open the front cover and remove old batteries. Once the old batteries are removed, wait 30
seconds before inserting the replacement batteries.
Note: Only use Energizer 1.5V AA alkaline batteries.
• Install new batteries as shown in the polarity indicated by the engraving. If the batteries are
installed incorrectly, in the reverse polarity, the indoor siren will not work. With typical use, the
WT4901/WT8901 batteries should be replaced every two years.
DO NOT TRY TO RECHARGE THESE BATTERIES. DISPOSAL OF USED BATTERIES MUST BE MADE
IN ACCORDANCE WITH THE WASTE RECOVERY AND RECYCLING REGULATIONS IN YOUR AREA.

Walk Test

Walk Test mode allows you to test the operation of each detector in the system. While in Walk Test
mode, the Ready, Armed, and Trouble LED's will flash to indicate that the Walk Test is active. The
Walk Test can be terminated at anytime by re-entering
The system will also automatically terminate the Walk Test on completion; it will sound an audible
warning (5 beeps every 10 seconds), beginning 5 minutes before the termination of the test.
1. Before testing, ensure that the system is disarmed and the Ready light is on.
2. Press
and close all zones to return the system to the Ready state.
3. Perform a System Test by following the steps in the previous section.
4. Press
,
5. To test the zones, activate each detector in turn (e.g., open each door/window or walk in
motion detector areas).
The System will display the following message when each zone (detector) is activated: 'Secure
System Before Arming < >', or 'Secure or Arm System'. Use the
zones are open. The message will disappear when the zones are closed.

Allowing Computer Access to your System

Occasionally, your installer may need to send information to or retrieve information from your
security system. Your installer will do this by having a computer call your system. You may need
to prepare your system to receive this 'downloading' call. To do this:
Press
[Master Code]
,
of time. During this time, the system will answer incoming downloading calls. For more informa-
tion on this feature, please ask your installer.

Reference Sheets

Fill out the following information for future reference and store this guide in a safe place.
System Information
Enabled?
FIRE
The Exit Delay Time is _______ seconds.
The Entry Delay Time is _______ seconds.
For Service
Central Station Information:
Account#: ___________________ Telephone#: __________________
Installer Information:
Company: ___________________ Telephone#: __________________
[Master Code]
at the keypad. This allows downloading for a limited period
AUXILIARY
,
to initiate the Walk Test.
12
[Master Code]
buttons to view which
PANIC
on the keypad.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents