Section 6 − Dynasty 280Dx Operation; Dynasty 280 Dx Controls - Miller Dynasty 280 Owner's Manual

Hide thumbs Also See for Dynasty 280:
Table of Contents

Advertisement

SECTION 6 − DYNASTY 280DX OPERATION
6-1.

Dynasty 280 DX Controls

1
.
For all front panel switch pad controls:
press switch pad to turn on light and en-
able function.
.
Green on nameplate indicates a TIG
function, Gray indicates a Stick func-
tion.
1
Standby Button
Use to turn machine on and off for daily oper-
ation.
2
Encoder Control
Use encoder control in conjunction with ap-
plicable front panel function switch pads to
change values for that function.
.
3
4
3
Memory Card Port And Indicator
This port is used to add features to the ma-
chine and update software to the boards
within the machine. Indicator is lit while card
is being accessed.
4
Volt Meter
Displays actual voltage when voltage is
present at the weld output terminals. It is also
used to display parameter descriptions
while in the menu.
5
Ammeter
Displays actual amperage while welding and
preset amperage while idle. It is also used to
display parameter selection options while in
the menu.
A complete Parts List is available at www.MillerWelds.com
5
6
Amperage Control
Use this control in conjunction with the en-
coder to set the weld amperage or peak am-
perage if the Pulser is active.
2
6
227 220-C
OM-253 086 Page 35