Table 1 : Presser foot chopping duty
MEMSW
37
38
Remarks
01 : When OFF, PA- will appear on the display, and you can not enter the parameter setting mode.
When ON, PA| will appear on the display.
11 : When ON, thread trimming or no thread trimming can be set by thread trimmer key on the operation panel.
16 : When OFF, if the machine continuously runs for three minutes, EF1 (Overtime error) occurs.
17 : When ON, 18 is set to OFF.
18 : When ON, 17 is set to OFF.
35 : Operated by the setting of the parameter F3 and F4 when ON.
45 : When ON, the setting of the parameter d1 is ignored.
66 : When ON, the start position after the treadle is depressed backward is at the beginning of the pattern or the
position of the DIPSW2-3 setting.
67 : When ON, priority returns to the sideways position after the treadle is depressed backwards, but only when
sewing pattern 5**, 6**, 7**, 8**, or 9** is selected.
However, if memory switch "66" is ON, the setting for memory switch "66" has priority.
68 : When OFF, sewing starts from the zigzag section.
When ON, sewing starts from the plain stitch section.
71 : When ON, alternating front and backtack (N-backtack) stitches are sewn with the number of backtack stitches
and the backtack stitch width that have been previously entered. In other words, the number of stitches and the
stitch width for each N-backtacking operation are the same.
The method of entering the number of stitches and the zigzag width using the operation panel is the same as for
normal backtacking.
Furthermore, the switching timing can be adjusted in detail by means of the following parameters.
Switching timing from normal start backtack to reverse sewing. ----- H3
Switching timing from start backtack to normal zigzag sewing.------- b1
Switching timing from normal zigzag sewing to end backtack. ------- b3
Switching timing from reverse end backtack to normal sewing. ------ H4
Note 1 :
If the P-ROM label is MN-B or MN-C and the part code of the main PCB ends with -001, this function is not available.
Note 2 :
If the P-ROM label is MN-B or MN-C, this function is not available.
Note 3 :
If the part code of the main PCB ends with -001, No. 81-98 are not displayed.
Note 4 :
If the P-ROM label is MN-B-D and the part code of the main PCB ends with -001 and -101 this function is not
available.
ON : 1.0 msec
ON : 1.0 msec
OFF : 1.0 msec
OFF : 1.0 msec
ON
ON
LZ2-B855E,B856E
ON : 1.0 msec
OFF : 5.0 msec
ON
OFF
OFF
ON
8. ELECTRIC COMPONENTS
ON : 2.5 msec
OFF : 2.5 msec
OFF
OFF
8-20