<Twin type>
Indoor unit 1
Model
Indoor unit 2
Outdoor unit
Cooling capacity
Heating capacity
Power supply
Cooling
Electrical
characteristics
Heating
Fan
Fan unit
Standard air flow H/M/L
Motor
Sound pressure level
Sound power level
Power supply
Standard length
Min. length
Max. total length
Refrigerant
Refrigerant charging amount
pipe
(Charge-less up to 30m)
Height
difference
Fan
Fan unit
Standard air flow volume
Motor
Gas side
Connecting
pipe
Liquid side
Sound pressure level
Sound power level
Indoor unit
Running current
Power consumption
Power factor
EER
Energy efficiency class ∗
Running current
Power consumption
Power factor
COP
Energy efficiency class ∗
(m³/min.)
H/M/L
(dB•A)
H/M/L
(dB•A)
Outdoor unit
Outdoor lower
Outdoor higher
(m³/min.)
Main
Sub
Main
Sub
Cooling/Heating
(dB•A)
Cooling/Heating
(dB•A)
– 18 –
RAV-
SM562KRT-E
RAV-
SM562KRT-E
RAV-
SP1104AT(Z)(ZG)-E
(kW)
10.0
(kW)
11.2
1 phase 230V (220 – 240V) 50Hz
(A)
12.98 – 11.90
(kW)
2.77
(%)
97
3.61
A
(A)
13.12 – 12.03
(kW)
2.80
(%)
97
4.00
A
Cross flow fan
14.0 / 12.5 / 10.7
(W)
30
39 / 36 / 33
54 / 51 / 48
1 phase 230V (220 – 240V) 50Hz
(m)
7.5
(m)
3
(m)
50
(m)
30
(m)
30
Propeller fan
101
(W)
100 + 100
(mm)
15.9
(mm)
12.7
(mm)
9.5
(mm)
6.4
49 / 50
66 / 67
Revised 2: Jun., 2008
SM802KRT-E
SM802KRT-E
SP1404AT(Z)(ZG)-E
12.3
14.0
18.00 – 16.50
3.88
98
3.17
B
17.76 – 16.28
3.83
98
3.66
A
18.5 / 14.6 / 12.2
30
45 / 41 / 36
60 / 56 / 51
7.5
3
50
40g/m
(31m to 50m)
30
30
103
100 + 100
15.9
15.9
9.5
9.5
51 / 52
68 / 69
∗ : IEC standard