Lighting Instructions - Superior DRT2033 Installation And Operation Instructions Manual

Direct-vent gas fireplaces drt2000 series, drc2000 series
Table of Contents

Advertisement

Innovative Hearth Products
Superior™ DRT2000 and DRC2000 Direct-Vent Gas Fireplaces

LIGHTING INSTRUCTIONS

Millivolt Gas Valve
WARNING: If you do not follow these instructions exactly, a fire or explosion may result,
causing property damage, personal injury, or loss of life.
A.
This appliance has a pilot which must be lighted by a piezo igniter.
When lighting the pilot, follow these instructions exactly.
B.
BEFORE LIGHTING smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
1.
STOP! Read the safety information above on this page.
2.
(If applicable) Set the thermostat to lowest setting. Turn wall on/off
switch, unit mounted on/off switch or remote control switch OFF.
3.
Turn OFF all electric power to the appliance.
4.
Access the control compartment.
5.
Push in gas control knob slightly and turn clockwise
6.
Knob cannot be turned from PILOT to OFF unless knob is pushed in
slightly. Do Not force.
7.
Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow B in the
safety information above on this page. If you don't smell gas, go to
the next step.
8.
Find pilot — located in firebox on the same plane as the top of the
burner.
9.
Turn knob on gas control counterclockwise
10.
Push in control knob all the way and hold in. Immediately light the
pilot by triggering the piezo igniter (pushing the button) until pilot
lights. Continue to hold the control knob in for about 1 1/2 minutes
after the pilot is lit. Release knob and it will pop back up. Pilot
should remain lit. If it goes out, repeat steps 5 through 10.
1.
(If applicable) Set the thermostat to lowest setting. Turn wall on/off
switch, unit mounted on/off switch or remote control switch OFF.
2.
Turn OFF all electric power to the appliance if service is to
be performed.
3.
Access the control compartment.
64
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
to OFF.
to PILOT
TO TURN OFF GAS TO APPLIANCE
WARNING
Hot glass will cause burns.
Do not touch glass until cooled.
Never allow children to touch glass.
C.
Use only your hand to push in or turn the gas control knob. Never
use tools. If the knob will not push in or turn by hand, don't try
to repair it, call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
D.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
If knob does not pop up when released, stop and immediately
call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas
control knob to OFF, and call your service technician or
gas supplier.
11.
Turn gas control knob counterclockwise
12.
Close control compartment.
13.
(If applicable) Turn on all electrical power to the appliance.
14.
(If applicable) Set thermostat to desired setting. Turn wall on/off
switch, unit mounted on/off switch or remote control switch ON.
Gas Control Valve
OUT
IN
Gas control knob
4.
Push in gas control knob slightly and turn clockwise
Do not force.
5.
Close the main line gas shut-off valve.
6. Close control compartment.
Operation
900004-00, 04/2014
to ON.
Pilot Assembly
to OFF.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: