Superior DRT2033 Installation And Operation Instructions Manual page 47

Direct-vent gas fireplaces drt2000 series, drc2000 series
Table of Contents

Advertisement

Innovative Hearth Products
Superior™ DRT2000 and DRC2000 Direct-Vent Gas Fireplaces
Figure 43: Millivolt Pilot
12. Use pipe joint compound or Teflon
NOTE: Ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds
on flare fittings.
13. Retrieve the burner and hold the venturi tube above the orifice. Place the shutter adjusting rod in the slot of the
shutter arm (Figure 38). Set the burner assembly into its position and secure the trapezoidal plate with the two
screws previously removed.
14. Reinstall the baffle with the two baffle securing screws.
15. Reassemble the remaining components.
16. Turn on gas supply and test for gas leaks (Page 37).
17. Relight the main burner. The lighting instructions can be found on the lighting label in the control compartment
or Page 64. Verify proper burner ignition and operation (Page 38).
18. Inspect the pilot system for proper flame. The pilot flame should engulf the flame sensor (Figure 36 and
Figure 37).
19. Using a manometer, test the inlet and manifold gas pressures (Table 3 and Table 4).
NOTE: Always test pressures with the valve regulator control at the highest setting.
Pilot
Pilot
Orifice
Orifice
®
Figure 44: Orifice
tape on all pipe fittings before installing.
Operation
900004-00, 04/2014
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drc2033Drc2035Drt2040Drc2040Drt2045Drc2045 ... Show all

Table of Contents