Superior DRT2033 Installation And Operation Instructions Manual page 16

Direct-vent gas fireplaces drt2000 series, drc2000 series
Table of Contents

Advertisement

Innovative Hearth Products
Superior™ DRT2000 and DRC2000 Direct-Vent Gas Fireplaces
Table 11: Fireplace Framing Specifications
Model
A *
DRC2033 /
33 3/4
DRT2033
857
DRC2035 /
35 1/4
DRT2035
895
DRC2040 /
40 1/4
DRT2040
1022
DRC2045 /
45 1/4
DRT2045
1149
C = Minimum height of top vent installations
E = Minimum height of rear vent installations
* Minimum opening size; additional 1/8" per side is recommended.
NOTE: Framing specifications do NOT apply for flexible venting.
When using flexible venting, refer to the kit requirements for
framing specifications.
NOTE: See Page 28 concerning use of compact terminations on
rear-vent 45" Models.
Table 12: Fireplace Framing Specifications—Corner Installation with Horizontal Termination
Model
A
33 3/4
51 1/4
DRC/T2033
857
1302
35 1/4
59 1/2
DRC/T2035
895
1511
40 1/4
63 13/16
DRC/T2040
1022
1621
45 1/4
70 3/8
DRC/T2045
1149
1788
Table 13: Fireplace Specifications
L
N
Top View
Model
DRC2033 / DRT2033 30 1/8 (765) 26 1/4 (667) 18 5/16 (465)
DRC2035 / DRT2035 32 1/4 (819) 28 3/4 (730)
DRC2040 / DRT2040 37 1/8 (943) 33 1/4 (845)
16
DRC2045 / DRT2045 37 1/4 (946) 33 1/4 (875)
B
C
33 1/4
36 7/8
845
930
35 1/4
38 3/4
895
984
40 1/4
43 3/4
1022
1111
40 1/4
43 3/4
1022
1111
B
C
D
E
36 1/4
25 5/8
12 1/8
921
651
308
42 1/16
3. 1/4
14 1/4
1068
768
362
45 11/32
32 3/16
15 7/8
1152
818
403
49 3/4
35 1/4
17 1/2
1264
895
445
NOTE: When finishing the area around the hood, 5/8" clearance above hood is required for hood installation.
K
O
E
E
F
G
22 1/4 (565)
27 1/4 (692)
25 1/2 (648)
D
E
NOTE: Dimension "D" is the
required framing depth when
14 1/2
19 5/8
368
499
the finish material (drywall)
thickness is 1/2" (13mm).
18
23 3/8
447
594
Vent Framing—Top Vent
with One 90° Elbow
18
28 1/4
447
717
18
28 1/4
447
717
B
Inches (millimeters)
F
G
5 1/2
14 1/2
140
368
6 5/8
18
168
457
8 1/2
18
216
457
10 1/4
18
260
457
Back wall of chase/enclosure (including finishing materials)
J
G
H
F
Blower
access panel
M
Front View
H (door)
J
30 1/2 (775)
33 5/8 (854)
21 7/8 (556) 10 15/16 (278)
32 3/8 (822)
35 1/4 (895)
37 3/8 (949)
40 1/4 (1022)
42 3/8 (1076)
45 1/4 (1149)
C
E
D
1/2 A
A
E
C
G
A
B
Hood
Junction
box access
Gas line
access
Left Side View
K
L
M
31 (787)
25 (635)
12 1/2 (317)
32 7/8 (835)
30 (762)
15 (381)
37 7/8 (962)
35 (889)
17 1/2 (445)
42 7/8 (1089) 10 1/16 (256)
Installation
900004-00, 04/2014
Framing
construction to be
10 1/2
2 x 4, or larger.
(267)
7 (178)
5 1/8
12 1/8
(130)
(308)
F*
7
(178)
D
Inches
(millimeters)
Right Side View
N
O
8 1/8 (207)
14 (356)
10 1/16 (256)
17 (432)
10 1/16 (256)
17 (432)
17 (432)