CAUTION
CAUTION
• Be sure to refer to the wiring system diagram
labeled inside the front panel.
• Check local electrical regulations for any
specific wiring instructions or limitations.
Cord clamp
Terminal cover
Screw
Screw
Screw
Connecting cable
Stripping length of the connecting cable
NOTE :
• Use stranded wire only.
• Wire type : More than H07RN-F or 245 IEC66
2
(1.0 mm
or more.)
How to install the air inlet grille on the indoor unit
• When ataching the air inlet grille, the contrary of
the removed operation is performed.
10-3-5. Piping and Drain Hose Installation
Piping and drain hose forming
• Since condensation results in machine trouble,
make sure to insulate both the connecting pipes
separately.
(Use polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
Fig. 10-3-10
Terminal block
Earth line
Connecting cable
110 mm
Earth line
10 mm
10 mm
50 mm
1. Die-cutting front panel slit
Cut out the slit on the left or right side of the front
panel for the left or right connection and the slit
on the bottom left or side of thefront panel for the
bottom left or right connection with a pair of
nippers.
2. Changing drain hose
For left connection, left-bottom connection and
rear-left connection's piping, it is necessary to
relocate the drain hose and drain cap.
How to remove the drain cap
Clip drain cap with needle-nose pliers, and pull out.
How to remove the drain hose
The drain hose is secured in place by a screw.
Remove the screw securing the drain hose, then pull
out the drain hose.
Heat insulator
Drain hose
How to attach the drain cap
1. Insert hexagonal wrench (4 mm).
4 mm
54
FILE NO. SVM-11015
Fig. 10-3-11
Fig. 10-3-12
Fig. 10-3-13