Toshiba RAS-10SKVP2-E Service Manual page 103

Split type indoor unit high wall, heat pump type outdoor unit heat pump type
Table of Contents

Advertisement

No.
Part name
Electronic
expansion valve
coil
Š
Fan guard
Procedure
1. Detachment
1) Perform step 1 in
and 1 in
.
2) Remove the coil by pull it upward.
2. Attachment
1) Insert a valve coil to value body by push
it downward. And confirm to fix it surely.
1. Detachment
1) Perform work of item 1 of
2) Remove the front cabinet, and put it down
so that fan guard side directs downward.
Perform work on a corrugated cardboard,
cloth, etc. to prevent flaw to the product.
3) Remove the hooking claws by pushing minus
screwdriver according to the arrow mark in
the right figure, and remove the fan guard.
2. Attachment
1) Insert claws of the fan guard in the holes
of the front cabinet. Push the hooking
claws (9 positions) by hands and fix the
claws.
Check that all the hooking claws are fixed
to the specified positions.
ƒ
, all the steps in
.
102
FILE NO. SVM-11015
Remarks
Minus screwdriver
Hooking claw

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents