Refrigerant Cycle Diagram - Toshiba RAS-10SKVP2-E Service Manual

Split type indoor unit high wall, heat pump type outdoor unit heat pump type
Table of Contents

Advertisement

7-1. Refrigerant Cycle Diagram

Pressure measurement
P
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm (10,13)
: 12.7mm (16)
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
NOTE :
• The maximum pipe length of this air conditioner is 25 m. When the pipe length exceeds 15m, the additional
charging of refrigerant, 20g per 1m for the part of pipe exceeded 15m is required. (Max. 200g)
7. REFRIGERANT CYCLE DIAGRAM
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
DA111A1F-20F1
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
Temp. measurement
T1
Tcj
TC
TA
TO
Split capillary
Ø1.2 x 80
Ø1.2 x 80
TE
NOTE :
18
FILE NO. SVM-11015-1
Max.
Min.
Chargeless : 15m
Charge : 20g/m
(16 to 25m)
Muffler
Strainer
Pulse Modulating
valve at liquid side
Refrigerant amount : 1.05kg
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
: 25m
: 2m