CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6
Indoor Unit
AUTO
OFF / ON
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
Operation Indication Lamps (LED)
•
(Green) ......... Lights up in operation,
POWER
•
(Orange) ......... Lights up in Quiet Mode
QUIET
•
(Orange) ......... Lights up in Timer
TIMER
•
POWERFUL
•
(Green) ............ Lights up in Ionizer
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Quiet Operation
• To provide extra quiet operation.
blinks in Automatic
Operation Mode judging.
Operation.
Setting.
(Orange) ... Lights up in Powerful
Mode Operation.
Mode Operation.
Random Auto Restart Control
• Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Ionizer Control
• Ionizer control for generate negative ion in
discharge air.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Cooling : Fan rotates at Hi, Me and SLo
– Soft Dry : Fan rotates at Lo- speed.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Starting Current Control
• Fan motor is delayed for 1.6 seconds when
compressor starts simultaneously.
Time Delay Safety Control
• Restarting is inhibited for appro. 3
minutes.
7 Minutes Time Save Control
• Cooling Operation only.
4
speed. Deodorizing control is
available.
Deodorizing control is
available.