CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6

Indoor Unit

AUTO
OFF / ON
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
Operation Indication Lamps (LED)
(Green) ......... Lights up in operation,
POWER
(Orange) ......... Lights up in Quiet Mode
QUIET
(Orange) ......... Lights up in Timer
TIMER
POWERFUL
(Green) ............ Lights up in Ionizer
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Quiet Operation
• To provide extra quiet operation.
blinks in Automatic
Operation Mode judging.
Operation.
Setting.
(Orange) ... Lights up in Powerful
Mode Operation.
Mode Operation.
Random Auto Restart Control
• Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Ionizer Control
• Ionizer control for generate negative ion in
discharge air.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Cooling : Fan rotates at Hi, Me and SLo
– Soft Dry : Fan rotates at Lo- speed.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Starting Current Control
• Fan motor is delayed for 1.6 seconds when
compressor starts simultaneously.
Time Delay Safety Control
• Restarting is inhibited for appro. 3
minutes.
7 Minutes Time Save Control
• Cooling Operation only.
4
speed. Deodorizing control is
available.
Deodorizing control is
available.