Note:
1. 24 times checking: Actual Ion ON for 10s & OFF for 1s 30 min continuously for 24 times.
2. 24 times count will be cleared when following conditions happen.
a) 24 times count over, b) Ionizer cancel if press Ion button or power reset, c) Ion f/b sgnl OK.
3. Error protection will be cleared when following conditions happen.
a) Power reset, b) Remocon operation ON/OFF button press, c) Forcible operation press, d) Opt OFF due to Timer OFF
4. Ion auto restart: Ion will auto restart if Actual Ion was ON with no error protection control before power shutdown. Otherwise
Ion will not auto restart.
5. Ion LED blinking can ON/OFF during error protection by following conditions:
a) Press remocon ion button
b) Press emergency opt SW to OFF blinking.
CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6