CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6
Net Weight
Compressor
Motor
Rated
Air Circulation
Motor
Rated
Fan Speed
Heat Exchanger
Description
Tube material
Fin material
Fin Type
Row / Stage
FPI
Size (W × H × L)
Refrigerant Control Device
Refrigeration Oil
Refrigerant (R-22)
Thermostat
Protection Device
Unit
lb (kg)
Type
Type
Output
kW
Type
Material
Type
Input
W
Output
W
Low
rpm
Medium
rpm
High
rpm
SuperHigh
rpm
mm
3
(cm
)
g (oz)
CS-C12CK
(1)
(3)
20 (9.0)
(4)
(2)
20 (9.0)
(1)
(3)
(4)
(2)
Cross-flow Fan
AS + Glass Fiber 20%
Induction (4-poles)
(1)
(3)
44.8 - 53.5
(4)
(2)
44.8 - 53.5
(1)
(3)
15
(4)
(2)
15
(1)
(3)
900 - 900
(4)
(2)
900
(1)
(3)
1,080 - 1,080
(4)
(2)
1,080
(1)
1,260 - 1,260
(4)
(2)
1,260
(3)
1,260 - 1,260
(1)
(3)
1,300 - 1,300
(4)
(2)
1,300
Evaporator
Copper
Aluminium (Pre Coat)
Slit Fin
(Plate fin configuration, forced draft)
(2)
2 × 15
(1)
(3)
2 × 15
(4)
21
(2)
610 × 315 × 25.4
(1)
(3)
610 × 315 × 25.4
(4)
(1)
(3)
(4)
(2)
(1)
(3)
(4)
(2)
Electronic Control
12
CU-C12CK
77 (35.0)
73 (33.0)
Rotary (1 cylinder) rolling
piston type
Induction (2-poles)
1.10
0.85
Propeller Fan
PP Resin
Induction (6-poles)
67 - 75
72.4 - 78.9
35
30
830 - 840
830
830 - 855
Condenser
Copper
Aluminium (Blue/Gold Coat)
Louver Fin
1 × 20
2 × 24
16
841 × 508 × 22
720 × 504 × 22
Capillary Tube
SUNISO 4GSI (410)
SUNISO 4GDID or ATMOS
M60 (350)
950 (33.5)
780 (27.5)
2 Stage Overload Protector