GENERAL INSTRUCTIONS

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48" FROM THE
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING
GAS LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE
PRESSURE TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.
USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING
COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
Thoroughly clean the chimney, fl ue and existing appliance before installing the new appliance into it. Do not
burn solid fuels in any appliance that is equipped with this gas log set.
The installation of this appliance must conform with local codes or in the absence of local codes, it must con-
form to ANSI Z.223.1 or the CAN/CGA B149.
Do not operate appliance in the presence of gasoline or other fl ammable liquids and vapours. Keep area clear
of other combustible materials. The appliance and its shut off must be disconnected from the gas supply piping
system before any pressure testing of the system is done.
Installation practices vary from region to region and it is important to know the specifi cs that apply to your area,
For example: in Massachusetts State:
The appliance off valve must be a "T" handle gas cock.
The fl exible connector must not be longer than 36 inches.
The appliance is not approved for installation in a bedroom or bathroom unless the appliance is a
direct vent sealed combustion product.
Un-vented room appliance shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00
through 7.00.
Sellers of un-vented propane or natural gas-fi red space/room appliances shall provide to each pur-
chaser a copy of 527 CMR 30.00 upon the sale of the appliance from
http://www.napoleonfi replaces.com/Webshare/installation_manuals/mass_requirements.pdf
A carbon monoxide detector is required in all rooms containing gas fi red appliances.
WITH THE GLASS DOOR OPENED OR REMOVED.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
FRONT FACE OF THE UNIT.
FIRE RISK. EXPLOSION HAZARD.
WARNING
!