A.O. Smith T-D2-OS Service Manual page 45

On-demand water heater
Table of Contents

Advertisement

Error Code
761
Miscommunication between Parent and Child
units for Easy Link systems.
1 Inspect cable connections between Parent and Child units.
2 Check for signs of power surges.
Error Code
Imperfect combustion
991
(Refer to section 12-3)
1 Check the gas type of the water heater.
2 Check how long the water heater has been installed and in use.
3 Check the installation place.
4 Check the altitude/elevation of area of where the water heater installed.
5 Check the vent length.
6 Check if there is any blockage in the intake air and/or exhaust.
7 Check if there is dust and lint in burner and heat exchanger, when the water
heater has been installed in laundry room.
8 Check if there is grease and dirt in burner and fan motor, when the water
heater has been installed in restaurant.
9 Check the manifold pressure in the water heater.
Malfunction description
Malfunction description
T-D2-IN / T-D2-OS Service Manual
Restoring
among all the water heaters. When the
computer detects proper connections
among all the water heaters, "761" error
code will cease to display.
Diagnosis
Turn off the power or water supply
If not possible, press and hold the INC
and DEC buttons on the computer board
simultaneously for more than 3 sec.
Diagnosis
45
CONFIDENTIAL
Ver. 1.00
Cancellation method
proper
cable
connections
Checkpoint
Cancellation method
Checkpoint