A.O. Smith T-D2-OS Service Manual page 13

On-demand water heater
Table of Contents

Advertisement

Check-
Part and Description
point
H1
Gas proportional valve
H2
Flow sensor
Air-fuel ratio rod
I
Flame rod
J
Flow adjustment valve
J1
Bypass valve
K
Pump connector port
T-D2-IN / T-D2-OS Service Manual
Color of wires
White - red
Red - Black
White - Black
Yellow - AFR rod
(Between AFR rod and
the computer board)
Orange - Flame rod
(Between flame rod and
the computer board)
Red - Black
Red - Black
White - Black
13
CONFIDENTIAL
Ver. 1.00
Normal range
1 to 15 VDC
(during operation)
and
20 to 40 Ω
4 to 5.5 VDC
1 to 4 VDC (pulse)
1,080 pulse / min
(more than 18 Hz)
More than 0.5 μA
(during operation)
More than 1 μA
(during operation)
7 to 16 VDC and
0.09 to 0.2 kΩ
7 to 16 VDC and
0.09 to 0.2 kΩ
Less than 1.3 Ω