Abs Operation Signal - Subaru Forester 2001 Service Manual

Chassis section
Hide thumbs Also See for Forester 2001:
Table of Contents

Advertisement

DIAGNOSTICS CHART WITH DIAGNOSIS CONNECTOR
ABS (DIAGNOSTICS)
AB: SELECT MONITOR
Applicable cartridge of select monitor: <Ref. to
ABS-10, Special Tools, PREPARATION TOOL,
General Description.>
NOTE:
For basic handling of the select monitor, refer to its
Operation Manual.
AC: TROUBLE CODES ARE
DISPLAYED.
S006522E51
A maximum of 3 trouble codes are displayed in
order of occurrence.
¼ If a particular trouble code is not properly stored
in memory (due to a drop in ABSCM&H/U power
supply, etc.) when a problem occurs, the trouble
code, followed by a question mark "?", appears on
the select monitor display. This shows it may be an
unreliable reading.
¼ *a* refers to the troubles in order of occurrence
(Latest, Old, Older and Reference).
Display screen
Contents to be monitored
The most recent trouble code appears
Latest
on the select monitor display.
The second most recent trouble code
Old
appears on the select monitor display.
The third most recent trouble code
Older
appears on the select monitor display.
A specified period of time proceeding
Reference
trouble code appears on the select
monitor display.
AD: CLEAR MEMORY
Contents to be monitored
Display screen
Function of clearing trouble code and
Clear memory?
freeze frame data.
S006522E48
S4M0076A
S006522E33
ABS-88
AE: ANALOG DATA ARE
DISPLAYED.
S006522E29
Display screen
Contents to be monitored
Wheel speed detected by the Front
FR wheel speed
Right ABS sensor is displayed in km/h
or mile/h.
Wheel speed detected by the Front Left
FL wheel speed
ABS sensor is displayed in km/h or
mile/h.
Wheel speed detected by the Rear
RR wheel speed
Right ABS sensor is displayed in km/h
or mile/h.
Wheel speed detected by the Rear Left
RL wheel speed
ABS sensor is displayed in km/h or
mile/h.
Stop light switch monitor voltage is dis-
Stop light switch
played.
Refers to vehicle acceleration detecting
G sensor output
by the analog G sensor. It appears on
voltage
the select monitor display in volts.
AF: ON/OFF DATA ARE
DISPLAYED.
S006522E43
Display screen
Stop light switch
Stop light switch signal
Valve relay signal
Valve relay signal
Motor relay signal
Motor relay signal
ABS operation signal from ABS
ABS signal to TCM
control module to TCM
ABS warning light
ABS warning light
Valve relay monitor
Valve relay operation monitor signal
Motor relay operation monitor signal
Motor relay monitor
ABS operation signal from ABS
CCM signal
control module to TCM
AG: ABS SEQUENCE CONTROL
S006522E23
Display
Contents to be monitored
screen
Perform ABS sequence
ABS
control by operating valve
sequence
and pump motor sequen-
control
tially.
Contents to be monitored
Index No.
<Ref. to ABS-11,
ABS Sequence
Control.>