Test Procedures
Making a Receiver Sensitivity Measurement
CDMA CELLULAR MOBILE RECEIVER TEST
T est Statu s
Con nected
Service O pt 2/9
Tes ting
Pass ed
Failed
M ax Frames
M ax Frames
M eas Cntl
Sin gle / Con t
1 000 0
Con fiden ce
95.0 0
FER Sp ec
0.5 0
Disp lay
Interim
Results
Yes / No
Now that you have a service option 002 call
connected, you are ready to make parametric
receiver and transmitter measurements. To
perform receiver measurements:
1.Go to the RX Test screen
2.Notice that the RX Test screen also has call
status indicators that show if the call is still
connected and if the call is a service option
002 call.
3.The parameter used to evaluate CDMA
receiver quality is frame-error-rate. To setup a
FER measurement with the HP 8924C, you
need to enter three parameters: Max Frames,
Confidence, and FER Spec.
4.Enter 10,000 into the Max frames field. This
sets an upper bound to the time limit of the
test.
FE R
0.00
E rro rs Co unted
Frames Cou nted
Traffic
Data Mo de
Sctr A Pwr
Svc O pt 2
-1 00 .0
dBm / BW
Traffic
%
Data Rate
-15 .6
Full
dB
%
E b / Nt
AW GN
--------
Off
To make an FER Measure-

ment:

%
•Enter the Maximum number of
frames to Test: 10,000
0
•Enter the Confdence: 95%
36 7
•Enter the Target FER Specifcation:
T o Screen
0.5%
CD M A
•Enable the display of interim results:
C ALL CNT L
Yes
Analog
RX TE ST
Arm the Measurement
Co nfig
P RNT CNFG
•Place the cursor at the "Cont" feld
under Meas Cntl
•Push the Knob
5.Enter 95% into the Confidence field. This
field sets the desired confidence limit for the
test. If confidence limit testing is not desired,
you can turn this field off. In that case, the
FET test will run until the number of frames
tested reaches the value entered into the Max
Frames field.
6.Enter 0.5% into the FER spec field. This field
sets the desired FER specification to test to.
7.Make sure that the Display Interim Results
field is set to yes.
8.Use the knob to place the cursor in front of the
Arm field. Press the knob to start the measure-
ment.
45