  • Page 1 LOW TEMP WAREWASHERS X-32 Technical Manual 2003 02...
  • Page 2 If you find any discrepancy or can't find certain information, please contact us. We will be glad to be of assistance. JET-TECH SYSTEMS 5771 Ferrier street Montreal, Quebec H4P 1N3 Tel.: 888-275-4538 (888-ASK-4-JET) ; 514-737-9701 Fax: 514-342-3854 e-mail: service@jet-tech.com...
  • Page 3: Manufacturer's Limited Warranty

    Systems, within the continental United States of America or Canada; provided that: prior authorization for this labor was approved by Jet-Tech Systems, the service work was performed by an authorized Jet Tech service agency; and that this agency installed an original and genuine Jet Tech part in the machine. Any repair work performed by a non-authorized service depot remains the sole responsibility of the user, and Jet Tech Systems will not be held responsible.
  • Page 4: Construction Features

    Slide-out front control panel provides easy access for service.  Overall dimensions: height: 33.5 in. (85 cm) Width 23.75 in. (60 cm) Depth: 23.75 in. (60 JET TECH SYSTEMS CORP. TEL: (514) 737 9701 FAX (514) 342 3854 1 888 275 4538 WWW.JET-TECH.COM SALES@JET-TECH.COM...
  • Page 5: Water Inlet

    DRAIN The X‐32 is equipped with an automatic drain pump that will pump the drain water to a maximum height of 36" (0.9 meter). A 1" ID flexible drain hose is included to facilitate maintenance and servicing of the machine. It is important not to reduce the size of this hose.
  • Page 6 ELECTRICAL Unit must be connected with a 110 volts 60Hz line. The terminal block will receive L1, N and Ground wire. Unit must be well grounded. Breaker rating should be 15 amps.
  • Page 7: Getting Started

    Getting Started Immediately upon receipt of your new X-32 dishwasher, inspect the dishwasher for any obvious signs of damage. If you do find any traces of damage, contact the transport company that brought the dishwasher to your place at once.
  • Page 8: Installation Checklist

    Chemical hook-up This unit is equipped with three (3) chemical pumps. Each will inject a different liquid product at a specific time during the wash cycle. The chemical pumps have sufficient length of tubing hose that can be inserted in gallon containers near the dishwasher.
  • Page 9: Operation

    OFF position. Second function: is for de-lime. The operator must put the de-liming chemical product in the water in the wash tank of X-32 and then push the black button. When the de-lime...
  • Page 10: Electrical Schematics

    Electrical Schematics DPS - Drain pump By-pass switch MPS - Drain Pump TL - Main Power switch PS1, PS2 - Pressure switches ER - Rinse solenoid valve EC - Fill solenoid valve MPD - Detergent pump MPB - Rinse additive pump MPSA - Sanitizer pump MP - Door switch TLS - Deliming option switch...