8-6. V-Sense Feeder Welding Mode - GMAW/FCAW Process

!
Weld terminals are energized at all
times in V-Sense Feeder welding
mode.
1
Mode Switch
2
Left Display
3
Right Display
4
Adjust Control
Setup
For typical system setup connections refer
2
25.0
to Section 8-5.
Rotate Mode Switch to V-SENSE FEEDER
position as shown.
The Left Display toggles between open cir-
cuit voltage and preset voltage.
Operation
The Adjust Control is used to set desired
preset voltage.
3
4
1
.
The Left Display toggling momentarily
pauses while the preset voltage is ad-
justed.
Arc Control (Inductance)
Rotate Arc Control to select desired induc-
tance setting from 0 to 100. Use lower in-
ductance settings to stiffen the arc and re-
duce puddle fluidity. Use higher inductance
settings to soften the arc and increase
puddle fluidity.