Replacing the Trigger Assembly
To replace the trigger assembly:
1. Remove the finger strap assembly.
2. Turn the RS419 upside-down.
3. Remove the set screw with
screwdriver.
4. Turn the trigger assembly
counter-clockwise until the exit
window and scan trigger align.
5. Lift the trigger assembly off the scan
assembly.
6. Align replacement trigger assembly
with scan assembly.
7. Rotate trigger assembly 1/4 turn
clockwise.
8. Tighten the set screw with
screwdriver.
9. Replace finger strap assembly.