AD Klima Fan Coil Unit Operation And Installation Manual

Fan coil unit

Advertisement

Quick Links

Fan Coil Unit
Operation and Installation Manual
One-Way Cassette Fan Coil
2 Pipe System FC02, 03, 04, 05
*Please read this manual before using the fan coil.
*Please keep this manual for future use

Advertisement

loading

Summary of Contents for AD Klima Fan Coil Unit

  • Page 1 Fan Coil Unit Operation and Installation Manual One-Way Cassette Fan Coil 2 Pipe System FC02, 03, 04, 05 *Please read this manual before using the fan coil. *Please keep this manual for future use...
  • Page 2: Table Of Contents

    Fan Coil Unit One-Way Cassette Type   Table of Contents 1. Safety and User Information………………………………02 2. Product Introduction………………………………………05 3. Controller operation………………………………………...10 4. Dimensions, Weight and Wiring diagram……………….12 5. Installation………………………………………………….14 6. Commissioning……………………………………………22 7. Maintenance and Troubleshooting…………………….24 Note: All illustrations and contents in this manual are provided for information only. We will continuously improve the products in aspects of product dimensions, performances, materials and structures without prior notification.
  • Page 3: Safety And User Information

    Fan Coil Unit One-Way Cassette Type 1. Safety and User Information 1.1 Safety instructions The One-Way Cassette fan coil units are developed and manufactured in accordance with the state-of-the-art technological standards and established technical safety norms and regulations. The One-Way Cassette fan coil units comply with the Machinery Safety Directive.
  • Page 4 Fan Coil Unit One-Way Cassette Type DANGER OF OVERHEAD LOADS! Wear a helmet and safety boots to prevent injury from falling components, especially when fitting the unit to the ceiling. Ceiling installations should always be performed by two people. PERSONAL INJURY! Always wear protective gloves when moving or fitting the unit to avoid injury from sharp edges.
  • Page 5 Fan Coil Unit One-Way Cassette Type supplier is not liable for any resulting damage: the user alone bears the full risk. The user is responsible for proper use. Proper use also stipulates the observance of the operation manual and the inspection and maintenance conditions defined by the manufactures.
  • Page 6: Product Introduction

    Fan Coil Unit One-Way Cassette Type 2. Product Introduction 2.1 Features and benefits Space saving One-Way Cassette fan coil maximize utilization of room space with recessed ceiling installation. Compact design as unit height only 235mm, easy for installtion. Stylish design Newly stylish and elegant design is in harmony with top interior decoration requirement.
  • Page 7 Fan Coil Unit One-Way Cassette Type DAMAGE TO THE UNIT! Please refer to unit name plate to know the right power supply! Wrong power supply may damage the motor and unit permanently! 2.4 Unit Components 1.Cover 10.Outlet water pipe assembly 19.Capacitor...
  • Page 9 Fan Coil Unit One-Way Cassette Type 2.6 Decorative panel DANGER OF ROTATING UNIT PARTS! Don't put fingers or any other things into the inlet/outlet and swing louver while the conditioner is in operation, because the high speed fan is very dangerous and may cause injuries.
  • Page 10 Fan Coil Unit One-Way Cassette Type Operation of remote controller and infrared signal from remote controller is correctly received. c) LED display When the air conditioner has malfunction, the self-diagnostic system will identify malfunction automatically and display malfunction code. Please refer to section "Malfunction and troubleshooting".
  • Page 11: Controller Operation

    Fan Coil Unit One-Way Cassette Type 3.Controller operation 3.1 Infrared controller   Fan Speed Swing Sleep Set Temp Louver Temp Clock On/Off Clock Slide Down Operation instruction: 1. ‘On/Off’ Button Press On/Off button to turn on/turn off the unit. 2. TEMP 'Up' 'Down' Button Press 'Up' or 'Down' button to increase or decrease the temperature desired.
  • Page 12 Fan Coil Unit One-Way Cassette Type Press the ‘TIMER ON’ button continuously, the timer will be changed in one minute intervals You can hold on the ‘TIMER ON’ button to speed up the time adjusting until reaches the desired time.
  • Page 13: Dimensions, Weight And Wiring Diagram

    Fan Coil Unit One-Way Cassette Type 4. Dimensions, Weight and Wiring diagram 4.1 Dimensions - Model FC02/FC03/FC04/FC05     Frequently used installation data Unit external dimension (W*D*H): 848*394*235mm Panel external dimension: 1043*468*30mm Hanging hook position dimension: 760mm*434mm Ceiling open dimension: (938~993)*(414~448)mm Other dimensions are marked in above fig.
  • Page 14 Fan Coil Unit One-Way Cassette Type 4.3 Wiring diagram Installation with motorized valve: Short-Connect connection port S6; Installation without motorized valve: Cut off connection port S6;  ...
  • Page 15: Installation

    Fan Coil Unit One-Way Cassette Type 5. Installation 5.1 Checking and acceptance Each fan coil is packaged in corrugated cartons to avoid damages during transportation, handling and site placement. To make sure no damages occurred due to transportation, please follow below...
  • Page 16 5.3 Temporary storage When storing the unit for a temporary period, the following points must be considered: Store the fan coil unit in its original packaging. The storage location must be weatherproof, dry and free of dust. Humidity must be between 50 and 85% r.h.
  • Page 17 Fan Coil Unit One-Way Cassette Type b) Ceiling requirement The intermediate ceiling is installed and a corresponding opening is available for the unit. There may not be any openings to the outside in the area of the intermediate ceiling. The entire intermediate ceiling area must be dry and sufficiently protected against humidity and moist air.
  • Page 18 Fan Coil Unit One-Way Cassette Type in section 4.1 Provide the fixing for the threaded rods with suitable tools. Fasten the threaded rods to the building ceiling. The length dimensions depend on the distance to the intermediate ceiling. Push the unit, with the terminal box facing front, into the intermediate ceiling at an angle, until the unit is fully placed into the intermediate ceiling.
  • Page 19 Fan Coil Unit One-Way Cassette Type a) Make sure the right direction of panel in order that the installation holes on the panel is corresponding to the unit, put two bolt in diagonal position ST4×10 and screw it but not tightly.
  • Page 20 Fan Coil Unit One-Way Cassette Type of the water inlet and outlet depends on the location of the water connection and/or the used valves. Below showed Fig. indicate the connection of a 2-way valve and 3-way valve to the units.
  • Page 21 Fan Coil Unit One-Way Cassette Type Use the self-provided stiff pipe and clamp with unit. Insert water pipe into water plug until it reaches the white tape. Tighten the clamp. Wind the drain hose using seal pad for installation. Insulate drain hose in the room.
  • Page 22 Fan Coil Unit One-Way Cassette Type standards and regulations currently in force must be observed and cleared with the local electricity company. 5.7.2 Unit electric wiring Please make the correct power supply connection according to the diagram located on the back of the cover of the sheet electric control box.
  • Page 23: Commissioning

    Fan Coil Unit One-Way Cassette Type 6. Commissioning ELECTRICAL HAZARD! Before carrying out any work on the unit, power the unit down to avoid injury from electrical current. Check that the unit is isolated and ensure that the appropriate point of the unit for the on-site power supply is secured against being switched back on.
  • Page 24 Fan Coil Unit One-Way Cassette Type knob is too tight, you may use a pair of pinchers to turn it anticlockwise until water flows out of the valve steadily, and then tighten the knob again. 6.1 Startup The One-Way cassette fan coil is controlled by infrared remote controller which can on/off the unit;...
  • Page 25: Maintenance And Troubleshooting

    7.1 Maintenance The One-Way Cassette fan coil unit is a high-quality and reliable unit. However, to guarantee the permanent functioning and performance of the unit, regular maintenance and inspection by technical experts is necessary.
  • Page 26 Fan Coil Unit One-Way Cassette Type 7.3 Quarterly maintenance The filter mat can be cleaned or replaced. It should be cleaned dry by a vacuum cleaner operated at medium or low capacity stage. Open the locks of the intake grille and remove the intake grille.
  • Page 27: Troubleshooting

    Fan Coil Unit One-Way Cassette Type 7.5.3 Troubleshooting Deviations from normal operating states of the fan coil units are evidence of malfunctions that must be investigated by maintenance personnel. The following table should serve as a starting point for maintenance personnel regarding possible causes of trouble and their correction.
  • Page 28 Fan Coil Unit One-Way Cassette Type Starting test of the pump Test float switch for function and mobility Not good sensor connection Check the sensor terminal connection or cable connection Sensor error Sensor broken Check sensor values if it is broken Insufficient water level detection Check if drain pan is dirty or blocked, clean the obstacles.
  • Page 29 Fan Coil Unit One-Way Cassette Type Remarks: ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… …………………………………………………………………………………………  ...
  • Page 30 Fan Coil Unit One-Way Cassette Type Remarks: ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… …………………………………………………………………………………………  ...
  • Page 31 Fan Coil Unit One-Way Cassette Type Remarks: ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… ………………………………………………………………………………………… …………………………………………………………………………………………  ...
  • Page 32       For Better Air! AD Klíma Hungária Kft 1113 Budapest, Karolina út 12. Tel.: +36 1 209-0186 Fax: +36 1 209-2597 web: www.ad-klima.hu Respect the environment! For a correct disposal, the different materials must be divided and collected according to the regulations in force.