Valcourt FP14 Cartier Installation And Operation Manual

Valcourt FP14 Cartier Installation And Operation Manual

Valcourt wood fireplace
Table of Contents

Advertisement

FP14 Cartier
Installation And Operation Manual 
Listed to standards ULC‐S610 and UL 127
US ENVIRONMENTAL PROTECTION AGENCY 
by Intertek Testing Services 
PHASE II CERTIFIED WOOD FIREPLACE
 
 
www.valcourtinc.com
Manufactured by: 
Stove Builder International Inc. 
250 rue Copenhague, Saint‐Augustin‐de‐Desmaures (Quebec), 
Canada,  G3A 2H3  Tel.: (418) 878‐3040    Fax: (418) 878‐3001 
This  manual  is  available  for  free  download  on  the  manufacturer's  web  site.  It  is  a  copyrighted  document. 
Re‐sale  is  strictly  prohibited.  The  manufacturer  may  update  this  manual  from  time  to  time  and  cannot  be 
responsible for problems, injuries, or damages arising out of the use of information contained in any manual 
 
obtained from unauthorized sources.
 
45355A
Printed in Canada
09-10-2014
READ AND KEEP THIS MANUAL FOR REFERENCE

Advertisement

Table of Contents
loading

Summary of Contents for Valcourt FP14 Cartier

  • Page 1 FP14 Cartier Installation And Operation Manual  Listed to standards ULC‐S610 and UL 127 US ENVIRONMENTAL PROTECTION AGENCY  by Intertek Testing Services  PHASE II CERTIFIED WOOD FIREPLACE     www.valcourtinc.com Manufactured by:  Stove Builder International Inc.  250 rue Copenhague, Saint‐Augustin‐de‐Desmaures (Quebec),  Canada,  G3A 2H3  Tel.: (418) 878‐3040    Fax: (418) 878‐3001  This  manual  is  available  for  free  download  on  the  manufacturer’s  web  site.  It  is  a  copyrighted  document.  Re‐sale  is  strictly  prohibited.  The  manufacturer  may  update  this  manual  from  time  to  time  and  cannot  be  responsible for problems, injuries, or damages arising out of the use of information contained in any manual ...
  • Page 2 This  heating  unit  is  designed  to  serve  as  a  supplementary  heat  source.  We  recommend  that  a  primary  heat source also be available in the home. The manufacturer cannot be responsible for costs associated  with the use of another heating system.  CAUTION:  Do  not  attempt  to  modify  or  alter  the  construction  of  the  fireplace  or  its  components.  Any  modification or alteration of construction may void the warranty, listings and approvals of this system. In  that case, Stove Builder International (SBI) will not be responsible for damages. Install the fireplace only as  described in these instructions.    FP14 Cartier - Installation and Operation Manual...
  • Page 3: Table Of Contents

        4.4.4 Firing Each New Load Hot ..................... 20     4.4.5 Turning Down the Air Supply ..................20     4.4.6 Building Different Fires for Different Needs ..............21     FP14 Cartier - Installation and Operation Manual...
  • Page 4: Maintaining Your Wood Heating System

        8.6.2 Offset Chimney Installation .................... 59     Angled Wall Radiation Shield .................... 63     Chimney Support Installation .................... 63     8.8.1 Universal Roof Support ....................63     FP14 Cartier - Installation and Operation Manual...
  • Page 5: Valcourt Limited Lifetime Warranty

    Appendix 6: Installation of Secondary Air Tubes and Baffle .... 87   Appendix 7: Exploded Diagram and Parts List ........91   VALCOURT LIMITED LIFETIME WARRANTY ........96     REGISTER YOUR WARRANTY ONLINE  To receive full warranty coverage, you will need to show evidence of  the date you purchased your unit. Keep your sales invoice.  We also  recommend that you register your warranty online at   http://www.valcourtinc.com/warranty‐registration.aspx     Registering your warranty online will help us track rapidly the  information we need on your unit.    FP14 Cartier - Installation and Operation Manual...
  • Page 6: Part A - Operation And Maintenance

    LIGHTER  FLUID,  OR  SIMILAR  LIQUIDS  OR  AEROSOLS  TO  START  A  FIRE  IN  THIS  FIREPLACE.  KEEP  ALL  SUCH LIQUIDS OR AEROSOLS WELL AWAY FROM THE FIREPLACE WHILE IT IS IN USE.  • DO NOT STORE FUEL WITHIN HEATER MINIMUM INSTALLATION CLEARANCES.   • BURN ONLY SEASONED NATURAL FIREWOOD.   • DO NOT BURN:  o GARBAGE OF ANY KIND,  o COAL OR CHARCOAL,  o TREATED, PAINTED OR COATED WOOD,  o PLYWOOD OR PARTICLE BOARD,  o FINE PAPER, COLORED PAPER OR CARDBOARD,  o SALT WATER DRIFTWOOD,  o MANUFACTURED LOGS CONTAINING WAX OR CHEMICAL ADDITIVES,  o RAILROAD TIES OR  o LIQUIDS SUCH AS KEROSCENE OR DIESEL FUEL TO START A FIRE.    FP14 Cartier - Installation and Operation Manual...
  • Page 7 * The US department of Housing and Urban Development describes “manufactured homes” better known as “mobile home” as followed; Buildings built on fixed wheels and those transported on temporary wheels/axles and set on a permanent foundation. PLEASE NOTE THAT THE PICTURES SHOWN IN THIS MANUAL ARE GENERIC  AND MAY NOT MATCH EXACTLY THE LOOK OF YOUR FIREPLACE.     FP14 Cartier - Installation and Operation Manual...
  • Page 8: General Information

    Firebox Volume  2 cu.ft. (0.057 m )   Maximum Log Length  16" east‐west***  Flue Outlet Diameter  6" (150 mm) diameter (vertical)   Baffle Material  Stainless steel with cement  Mobile home approved  No    * Burn time and heating capacity may vary subject to location in home, chimney draft, chimney diameter,  locality, heat loss factors, climate, fuels and other variables.  ** The EPA test fuel is dimensional Douglas fir pieces stapled together into cribs with air spaces between.  We  also  test  using  the  same  procedure  except  using  split  hardwood  firewood  to  reflect  real‐world  heat  output. This fireplace is not intended to operate at its peak heat output continuously.  *** East‐west: through the door you see the sides of the logs.  FP14 Cartier - Installation and Operation Manual...
  • Page 9           FP14 Cartier - Installation and Operation Manual...
  • Page 10           FP14 Cartier - Installation and Operation Manual...
  • Page 11: Zone Heating And How To Make It Work For You

            2.2 Zone Heating and How to Make it Work for You   Your new FP14 Cartier wood fireplace is a space heater, which means it is intended to heat the area it is  installed in, as well as spaces that connect to that area, although to a lower temperature. This is called zone  heating and it is an increasingly popular way to heat homes or spaces within homes.   Zone  heating  can  be  used  to  supplement  another  heating  system  by  heating  a  particular  space  within  a  home, such as a basement family room or an addition that lacks another heat source.  Houses of moderate size and relatively new construction can be heated with a properly sized and located  wood fireplace. Whole house zone heating works best when the fireplace is located in the part of the house  where the family spends most of its time. This is normally the main living area where the kitchen, dining  and living rooms are located. By locating the fireplace in this area, you will get the maximum benefit of the  heat it produces and will achieve the highest possible heating efficiency and comfort. The space where you  FP14 Cartier - Installation and Operation Manual...
  • Page 12: The Benefits Of Low Emissions And High Efficiency

    The  body  of  your  fireplace,  which  is  most  of  its  weight,  is carbon  steel.  Should  it  ever  become  necessary  many years in the future, almost the entire fireplace can be recycled into new products, thus eliminating  the need to mine new materials.  The paint coating on your fireplace is very thin. Its VOC content (Volatile Organic Compounds) is very low.   VOCs can be responsible for smog, so all the paint used during the manufacturing process meets the latest  air quality requirements regarding VOC reduction or elimination.  The air tubes are stainless steel, which can also be recycled.   The baffle is made of stainless steel and cement. It is not considered hazardous waste. Disposal at a landfill  is recommended.  Moulded refractory bricks are mainly composed of silicon dioxide, also known as silica, a product processed  from  a  mined  mineral.    It  is  most  commonly  found  in  nature  in  the  form  of  sand  and  clay.  Disposal  at  a  landfill is recommended. The steel mesh contained in some refractory bricks can be recycled.  FP14 Cartier - Installation and Operation Manual...
  • Page 13: Fuel

    Hardwoods  are  denser  than  softwoods.  People  who  live  in  the  coldest  regions  of  North  America  usually  have  only  spruce,  birch  and  poplar, other low‐density species to burn and yet they can heat their homes successfully.   FP14 Cartier - Installation and Operation Manual...
  • Page 14: Log Length

    Firewood  dries  more  quickly  when  it  is  split.  Large  unsplit  rounds  can  take  years  to  dry  enough  to  burn.  Even  when  dried,  unsplit  logs  are  difficult  to  ignite  because  they  don’t  have  the  sharp  edges  where  the  flames first catch. Logs as small as 3” (75 mm) should be split to encourage drying.                FP14 Cartier - Installation and Operation Manual...
  • Page 15: How To Dry Firewood

    • firewood  that  is  ready  to  burn  has  a  moisture  content  between15  and  20%  by  weight  and  will  allow  your fireplace to produce its highest possible efficiency  3.2.6 Judging Firewood Moisture Content  You can find out if some firewood is dry enough to burn by using these guidelines:  • cracks form at the ends of logs as they dry  • as it dries in the sun, the wood turns from white or cream colored to grey or yellow,  • bang two pieces of wood together; seasoned wood sounds hollow and wet wood sounds dull,  • dry wood is much lighter in weight than wet wood,  FP14 Cartier - Installation and Operation Manual...
  • Page 16: Manufactured Logs

    Section  8:  The  Venting  System  of  this  manual.  See  Appendix  5:  Installing  the  Fire  Screen  (AC01308) for installation instructions.  OPERATING  WITH  THE  FIRE  SCREEN  INCREASES  THE  POSSIBILITY  OF  GENERATING  CARBON  MONOXIDE.  CARBON MONOXIDE IS AN ODOURLESS GAS THAT IS HIGHLY TOXIC AND WHICH CAN CAUSE DEATH AT  HIGH CONCENTRATION IN AIR.  4.2 Your First Fires  Two things will happen as you burn your first few fires; the paint cures and the internal components of the  fireplace are conditioned.   FP14 Cartier - Installation and Operation Manual...
  • Page 17: Lighting Fires

    Once  the  fire  has ignited, close the door and leave the air control  fully open.    A conventional kindling fire with paper  under finely split wood.  DO NOT LEAVE THE FIREPLACE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED. ALWAYS CLOSE AND  LATCH THE DOOR AFTER THE FIRE IGNITES.  After the kindling fire has mostly burned, you can add standard firewood pieces until you have a fire of the  right size for the conditions.  CAUTION:  PLACE  THE  WOOD  LOGS  FAR  ENOUGH  FROM  THE  GLASS  TO  ALLOW  PROPER  PRIMARY  AIR  FLOW  FP14 Cartier - Installation and Operation Manual...
  • Page 18: The Top Down Fire

    Light  the  newspaper.   4.3.4 Using Fire Starters  Many people like to use commercial fire starters instead of newspaper. Some of these starters are made of  sawdust and wax and others are specialized flammable solid chemicals. Follow the package directions for  use.   Gel starter may be used but only if there are no hot embers present. Use only in a cold firebox to start a  fire.  DO NOT USE FLAMMABLE LIQUIDS SUCH AS GASOLINE, NAPHTHA, FUEL OIL, MOTOR OIL, OR AEROSOLS  TO START OR REKINDLE THE FIRE.   4.4 Maintaining Wood Fires  4.4.1 General Advice  Wood heating with a space heater is very different than other forms of heating. There will be variations in  the temperature in different parts of the house and there will be variations in temperature throughout the  day and night. This is normal, and for experienced wood burners these are advantages of zone heating with  wood.  Do not expect steady heat output from your fireplace. It is normal for its surface temperature to rise after a  new load of wood is ignited and for its temperature to gradually decline as the fire progresses. This rising  and falling of temperature can be matched to your household routines. For example, the area temperature  can be cooler when you are active, such as when doing housework or cooking, and it can be warmer when  you are inactive, such as when reading or watching television.  Wood burns best in cycles. A cycle starts when a new load of wood is ignited by hot coals and ends when  that load has been consumed down to a bed of charcoal about the same size as it was when the wood was  FP14 Cartier - Installation and Operation Manual...
  • Page 19: Ash Removal

    Rake  these  coals  towards  the  door  before  loading. There are two reasons for this raking of the coals. First, it concentrates them near where most of  the  combustion  air  enters  the  firebox  and  where  they  can  ignite  the  new  load  quickly,  and  second,  the  charcoal will not be smothered by the new load of wood. If you were to simply spread the charcoal out, the  new load will smoulder for a long time before igniting.    Remove ash first, and then rake charcoal towards the front of the firebox before loading so that it will ignite  the new load.  FP14 Cartier - Installation and Operation Manual...
  • Page 20: Firing Each New Load Hot

    With  good  fuel  and  correct  air  control  use,  the  flames  should  slow  down,  but  should  stay  large and steady, even as the air supply is reduced.  FP14 Cartier - Installation and Operation Manual...
  • Page 21: Building Different Fires For Different Needs

    Sometimes you will want to build a fire to last up to eight hours, but don’t need intense heat. In this case  use soft wood species and place the logs compactly in the firebox so the pieces are packed tightly together.  You will need to fire the load hot for long enough to fully char the log surfaces before you can turn the air  down. Make sure the fire is flaming brightly before leaving the fire to burn.  4.4.6.3 High Output Fires for Cold Weather  When the heat demand is high during cold weather, you’ll need a fire that burns steadily and brightly. This  is the time to use larger pieces of hardwood fuel if you have it. Put the biggest pieces at the back of the  firebox and place the rest of the pieces compactly. A densely built fire like this will produce the longest burn  your fireplace is capable of.  You will need to be cautious when building fires like this because if the air is turned down too much, the fire  could smoulder. Make sure the wood is flaming brightly before leaving the fire to burn.  4.4.6.4 Maximum Burn Cycle Times  The burn cycle time is the period between loading wood on a coal bed and the consumption of that wood  back to a coal bed of the same size. The flaming phase of the fire lasts for roughly the first half of the burn  cycle and the second half is the coal bed phase during which there is little or no flame. The length of burn  you can expect from your fireplace, including both the flaming and coal bed phases, will be affected by a  number of things, such as:   • firebox size,   • the amount of wood loaded,   • the species of wood you burn,  • the wood moisture content,  • the size of the space to be heated,   • the climate zone you live in, and  • the time of year.   FP14 Cartier - Installation and Operation Manual...
  • Page 22 East‐west  loads  are  excellent for long, low output fires for relatively mild weather.  North‐south  loads  break  down  more  quickly,  but  much  more  wood  can  be  loaded  at  a  time.  This  makes  north‐south loading good for high output, long lasting fires for cold weather.  FP14 Cartier - Installation and Operation Manual...
  • Page 23: Maintaining Your Wood Heating System

    If you see brown streaks coming from the edge of the glass, it is time to replace the gasket around the glass.  Visit  your  fireplace  retailer  to  get  the  self‐adhesive  glass  gasket  and  follow  the  instructions  below  for  installation.  Do not abuse the glass door by striking or slamming shut. Do not use the fireplace if the glass is broken.  FP14 Cartier - Installation and Operation Manual...
  • Page 24: Door Adjustment

    1. Using  a  Philips  screwdriver,  remove  the  handle  stopper  (A)  held  in  place  by two screws (B).    1. Turn  the  handle  counter  clock  wise  one  turn  to  increase  pressure.  To  reduce the pressure, when installing a  new  gasket  for  example,  turn  clock  wise.      FP14 Cartier - Installation and Operation Manual...
  • Page 25: Door Alignment

      2. Put  back  in  place  the  handle  stopper  (A) and the screws (B).  5.1.4 Door Alignment  1. Remove the door from the hinges.  FP14 Cartier - Installation and Operation Manual...
  • Page 26 2. loosen  the  pressures  screws  located  on  the  lower  and  upper  hinges  of  the  door  using  a  3/32” Allen key to free the adjustable hinge  rods.  3. Using a flat screwdriver, turn the adjustable  hinge  rods  in  the  direction  shown  to  adjust  the doors (see table below). Tighten all door  hinge pressure screws when they are at the  desired positions.        FP14 Cartier - Installation and Operation Manual...
  • Page 27: Replacing The Door Gasket

    1400º F. If the glass breaks, it must be replaced with one having the same specification. Contact your Valcourt dealer to obtain a genuine replacement part (see “replacement parts”, in appendix to get the proper part number).
  • Page 28 FP14 Cartier - Installation and Operation Manual...
  • Page 29: Cleaning And Painting The Fireplace

    Your  new  fireplace  has  the  right  characteristics  to  help  you  to  burn  clean  fires  with  little  or  no  smoke,  resulting in less creosote in the chimney.  5.2.2 How Often Should You Clean the Chimney?  It is not possible to predict how much or how quickly creosote will form in your chimney. It is important,  therefore, to check the build‐up in your chimney monthly when getting used to the new fireplace until you  determine the rate of creosote formation. Even if creosote forms slowly in your system, the chimney should  be cleaned and inspected at least once each year. Do not allow more than 1/8 (3 mm) creosote buildup in  the chimney.  FP14 Cartier - Installation and Operation Manual...
  • Page 30: Cleaning The Chimney

    Do  not  expect  chemical  cleaners  to  keep  your chimney clean.    The rain cap can be removed for inspection and/or cleaning of the chimney.  The chimney should be swept following these steps:  1) Remove the fire baffle and air tubes.  2) Remove the rain cap.  3) Sweep the chimney.  4) Clean the inside of the firebox.  5) Re‐install the baffle, the air tubes and the rain cap.  CAUTION:   OPERATION  OF  YOUR  FP14  CARTIER  WITHOUT  THE  BAFFLE  MAY  CAUSE  UNSAFE  AND  HAZARDOUS TEMPERATURE CONDITIONS AND WILL VOID THE WARRANTY.  FP14 Cartier - Installation and Operation Manual...
  • Page 31: Fire Baffle Removal Prior To Cleaning The Chimney

    5. Check  outside  to  ensure  that  sparks  and  hot  embers  coming  out  of  the  chimney  are  not  igniting  the  roof;  6. Do  not  use  the  fireplace  again  until  your  chimney  and  fireplace  have  been  inspected  by  a  qualified  chimney sweep or a Fire Department Inspector;    FP14 Cartier - Installation and Operation Manual...
  • Page 32: Part B - Installation

    MAY  RESULT  IN  HAZARDOUS  CONDTIONS.  WHERE  ANY  SUCH  CHANGES  ARE  PLANNED,  STOVE  BUILDER INTERNATIONAL INC. SHOULD BE CONTACTED IN ADVANCE.   • ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING  AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI NFPA 211 (USA).   • CONNECTION BETWEEN A 2100 INSULATED CHIMNEY AND A LISTED STAINLESS STEEL CHIMNEY LINER  IS ALLOWED IF A LISTED CONNECTOR IS USED. FOLLOW INSTRUCTIONS AT THE SECTION 8.9 FOR THAT  KIND OF INSTALLATION.  • IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM.  • DO  NOT  CONNECT  TO  OR  USE  IN  CONJUNCTION  WITH  ANY  AIR  DISTRIBUTION  DUCTWORK  UNLESS  SPECIFICALLY APPROVED FOR SUCH INSTALLATION.  FP14 Cartier - Installation and Operation Manual...
  • Page 33: Regulations Covering Fireplace Installation

    ANSI  NFPA  70  National  Electrical  Code  are  to  be  followed  in  the  absence  of  local  code  requirements.  NOTE:    The Fireplace is not approved for use with a so‐called “positive flue connection” to the clay tile of  a masonry chimney.  6.3 Fireplace Installation  6.3.1 Locating the FP14 CARTIER  A. The best location to install your fireplace is determined by considering the location of windows, doors,  and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the  heart  extension  and  the  mantel,  and  taking  into  consideration  the  location  of  the  hot  air  ducts  FP14 Cartier - Installation and Operation Manual...
  • Page 34 However,  the  upper  and  lower  angle,  for  the  full  width  of  the  floor  protection,  must  be  protected  2"  horizontally  and  vertically  (E)  by  a  non‐combustible  material.  For  example,  a  sheet  metal  (not  included).  Apart from these two corners, the sheet metal does not have to cover the rest of the wall between the base  of the fireplace and the floor.    MINIMUM  CLEARANCES  MEASUREMENTS  A  84" (2134 mm)  E  2" (51 mm)  8" (203 mm)  B  minimum      FP14 Cartier - Installation and Operation Manual...
  • Page 35     FP14 Cartier - Installation and Operation Manual...
  • Page 36   In the case where (F) would be equal to 4", it is suggested that the sheet metal between the base of the  fireplace and floor be in one piece.      FP14 Cartier - Installation and Operation Manual...
  • Page 37 In  the  case  where  the  fireplace  is  installed  directly  on  the  floor  or  on  a  raised  base  of  less  than  8",  an  R  value for the hearth extension is required. In these case also, the joint between the hearth extension and  the  fireplace  (E)  must  be  protected  by  a  non‐combustible  material.  For  example,  a  sheet  metal  (not  included).  Note that the floor under of the fireplace should match or exceed the height of the floor protection.      MINIMUM MEASUREMENT  E  2" (51 mm)    FP14 Cartier - Installation and Operation Manual...
  • Page 38 In  the  case  of  a  known  K  and  thickness  of  alternative  materials  to  be  used  in  combination,  convert  all  K  values  to  R  by  dividing  the  thickness  of  each  material  by  its  K  value.  Add  the  R  values  of  your  proposed  materials as shown in the previous example.   Example:   K value = 0.75   Thickness = 1   R value = Thickness/K = 1/0.75 = 1.33    FP14 Cartier - Installation and Operation Manual...
  • Page 39: Minimum Heart Extension Requirements

    2.2  Horizontal still air** (1/8")  0.135  0,920**  * Information as reported by manufacturers and other resources  ** For a 1/8" thickness. You cannot «stack» horizontal still air to accumulate R‐values; you must separate  each layer of horizontal still air with another non‐combustible material.  6.3.2 Minimum Heart Extension Requirements  The hearth extension floor area must extend at least 20" (508 mm)* in front of the hearth (A) and at least  8" (203 mm) on each side of the door opening (D). The joint between the hearth extension and the fireplace  hearth needs to be made of non‐combustible material such as sheet metal (not included).  *  On  a  raised  base  installation  of  more  than  8",  a  non‐combustible  hearth  extension  floor  area  must  extend  at  least  16" (406 mm) in front of the hearth.  FP14 Cartier - Installation and Operation Manual...
  • Page 40         CLEARANCES  A  20" (508 mm)*  B  38" (965 mm)  C  8" (203 mm)     *On a raised base installation of more than 8", a non‐combustible hearth extension floor area must extend  at least 16" (406 mm) in front of the hearth.    FP14 Cartier - Installation and Operation Manual...
  • Page 41: Framing, Facing, Mantel, And Combustible Shelf

    WARNING:  THE  FIREPLACE  MUST  NOT  BE  IN  CONTACT  WITH  ANY  INSULATION  OR  LOOSE  FILLING  MATERIAL.  FOR  THIS  PURPOSE,  COVER  THE  INSULATION  WITH  DRYWALL  PANELS  OR  ANY  OTHER FINISHING MATERIAL INSIDE THE CHASE AROUND THE FIREPLACE.                     FP14 Cartier - Installation and Operation Manual...
  • Page 42   LEGEND  Combustible material allowed in  this area  Non‐combustible material only in  this area    INSTALLATION WITHOUT SHELF     FP14 Cartier - Installation and Operation Manual...
  • Page 43 (K)  would  be  to  make  a  non‐combustible  heat  shield  (M)  that  meets  the  following  requirements:  Must  be  located exactly 1" bellow the combustible shelf (L). Must  have the same depth as the shelf to be protected. Must  have  at  least  the  same  width  as  the  fireplace  and  must  be perfectly centered with the shelf.    FP14 Cartier - Installation and Operation Manual...
  • Page 44   WALL FINISH BEHIND THE FIREPLACE’S FACEPLATE INSTALLATION.    LEGEND  Combustible material allowed in  this area  Non‐combustible material only in  this area      CLEARANCES  M*  37 3/4" (959 mm) MIN.  N*  25 3/4" (654 mm)  O*  1 1/4" (32 mm)  *When drywall panels or any other finishing material inside the chase around the fireplace is to be used,  add its thickness to the measurement.  FP14 Cartier - Installation and Operation Manual...
  • Page 45   See Appendixes for fresh air kit (P) and forced air kit (O) installation.  FRESH AIR INTAKE KIT OR FORCED AIR KIT INSTALLATION     LEGEND  Combustible material allowed in  this area  Non‐combustible material only in  this area    MINIMUM MEASUREMENTS  MINIMUM MEASUREMENTS    FOR FRESH AIR INTAKE (Q)**  FOR FORCED AIR KIT (P)**  R*  N/A  18" (457 mm)  S*  12" (305 mm)  N/A  *When drywall panels or any other finishing material inside the chase around the fireplace is to be used,  add its thickness to the measurement.  ** The fresh air intake kit can only be installed on the right side whereas the forced air kit may be installed  either on the sides or on the back.   FP14 Cartier - Installation and Operation Manual...
  • Page 46   LEGEND  Combustible material allowed in  this area  Non‐combustible material only in  this area      CLEARANCES**  T*  56 1/4" (1429 mm)  U*  82 3/8" (2092 mm)  *When drywall panels or any other finishing material inside the chase around the fireplace is to be used,  add its thickness to the measurement.  **Values M and N are minimum measurements. They may need to be increased to alloy installation of a  Fresh air intake kit or forced air kit, or depending on the finish material used.  FP14 Cartier - Installation and Operation Manual...
  • Page 47 Non‐combustible  material  such  as  brick,  stone  or  ceramic  tile  may  be  in  contact  with  the  fireplace  decorative frame. Note that if you ever needed to remove the decorative frame, it might be wise not to seal  between the faceplate and finishing material.  6.3.3.3 Compliance of a Combustible Mantel Shelf   To ensure compliance of an existing mantel shelf or to install a combustible mantel shelf, refer to table and  figure below. For example, a mantel shelf with a 6’’ depth (152 mm) ((C) value) must be installed at least  48"  (1219  mm)  ((B)  value)  above  the  bottom  of  the  fireplace  (see  figure  below).  Different  mantel  shelf  dimensions are listed in the following table. However, no combustible mantel shelf can be installed at less  than 48" (1219 mm) above the bottom of the fireplace.  If the depth of the mantel shelf is not listed in the  table below, add 44" (1118 mm) to the depth of your mantel shelf to obtain the safe positioning of your  mantel shelf. For example, for a 9" (229 mm) mantel shelf, the safe positioning would be 61" (1549 mm)    above the bottom of the fireplace 44" (1118 mm) + 9" (229 mm)).  FP14 Cartier - Installation and Operation Manual...
  • Page 48 (L).  Must  have  the  same  depth  as  the  shelf  to  be  protected.  Must  have  at  least  the  same  width  as  the  fireplace and must be perfectly centered with the shelf.  SHELF POSITIONING    CLEARANCES  B  C  A  84" (2134 mm)    48" (1219 mm)  6" (152 mm)  50" (1270 mm)  8" (203 mm)  52" (1321 mm)  10" (254 mm)  54" (1372 mm)  12" (305 mm)    FP14 Cartier - Installation and Operation Manual...
  • Page 49: Clearances To Combustible Material

    In  addition,  you  will  find  information  about  your  fireplace  (model,  serial  number,  etc.).  You  can  find  the  certification  label  on  the  fireplace bottom, behind the lower louver.    FP14 Cartier - Installation and Operation Manual...
  • Page 50: The Venting System

    Because  the  venting  system  is  the  engine  that  drives  the  wood  heating  system,  it  must  have  the  right  characteristics. The signs of bad system design are cold backdrafting when there is no fire in the fireplace,  slow kindling of new fires, and smoke roll‐out when the door is opened for loading.   8.4.1 Why the chimney should penetrate the highest heated space  When it is cold outside, the warm air in the house is buoyant so it tends to rise. This tendency of warm air  to rise creates a slight pressure difference in the house. Called ‘stack effect’, it produces a slightly negative  pressure  low  in  the  house  (relative  to  outside)  and  a  slightly  positive  pressure  zone  high  in  the  house.  If  there is no fire burning in a heater connected to a chimney that is shorter than the warm space inside the  house, the slight negative pressure low in the house will compete against the desired upward flow in the  chimney.  FP14 Cartier - Installation and Operation Manual...
  • Page 51: Chimney Installation Notes

    8. If  the  chimney  extends  higher  than  5  ft.  (1.5  m)  above  its  point  of  contact  with  the  roof,  it  must  be  secured using a roof brace.  9. A  rain  cap  must  be  installed  on  top  of  the  chimney.  Failure  to  install  a  rain  cap  may  cause  corrosion  problems.  FP14 Cartier - Installation and Operation Manual...
  • Page 52   10. Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a  2" (50 mm) minimum clearance between the chimney and any combustible materials. Do not fill this 2  space with insulation or any other combustible material.  11. Portions of the chimney which may extend through accessible spaces must be enclosed to avoid contact  with combustible materials or damage the chimney.      12. For installations where more than one chimney is located in the same non‐combustible chase or within  the same area, we suggest that their terminations be separated by at least 16" (410 mm) horizontally,  and  18"  (460  mm)  vertically.  This  separation  is  to  prevent  smoke  migrating  from  one  chimney  to  another.  FP14 Cartier - Installation and Operation Manual...
  • Page 53   18" 18" 457.2mm 457.2mm 18" 457.21mm 16" 16" 406.4mm 406.4mm   Note chimney chase on the roof must be the same size as the flashing : The FP14 Cartier - Installation and Operation Manual...
  • Page 54: Chimney Installation Instructions

    However,  starting  using  a  30° or 45° elbow is also approved.  Mandatory  measure  of  15  ft.  from  the  B  bottom  of  the  fireplace  to  the  top  of  the outside chimney.        FP14 Cartier - Installation and Operation Manual...
  • Page 55       Direct installation  Exterior offset installation  FP14 Cartier - Installation and Operation Manual...
  • Page 56 2. From below, install a firestop (A) supplied by the chimney manufacturer in each ceiling/floor separation  through which the chimney will pass. At the attic level, install a radiation shield from above (C).  3. Follow  the  chimney’s  manufacturers’  instructions  and  place  the  first  chimney  length  on  the  fireplace.  For  all  chimneys,  you  must  use  an  anchor  plate  (A)  supplied  by  the  chimney  manufacturer  before  FP14 Cartier - Installation and Operation Manual...
  • Page 57 4. Every  time  the  chimney  passes  through  a  ceiling  or  a  wall, install  the  appropriate  firestop.  When  you  reach the desired height, install the roof support (not illustrated). (Refer to instructions included with  the support).  5. Then, put the roof flashing (D) in place and seal the joint between the roof and the flashing with roofing  pitch. For sloping roofs, place the flashing under the upper shingles and on top of the lower shingles.  Nail the flashing to the roof, using roofing nails.  6. Place the storm collar (E) over the flashing, and tighten it with the bolt supplied. Finally, seal the joint  between the storm collar and the chimney, using silicone caulking.  7. Install the chimney cap (G).  8. When  a  ventilated  roof  flashing  is  installed,  precautions  are  to  be  taken  not  to  caulk  or  seal  the  ventilating openings.    FP14 Cartier - Installation and Operation Manual...
  • Page 58       THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED  NOTE: THE FLOOR AND WALLS BELOW THE ATTIC MUST BE INSULATED USING THE SAME INSULATION.  FP14 Cartier - Installation and Operation Manual...
  • Page 59: Offset Chimney Installation

    1. Install  the  first  elbow;  turn  it  in  the  required  direction.  Secure  it  to  the  chimney  according  to  the  chimney  manufacturer’s  instructions.    In  many  cases,  it  is  recommended  to  secure  connections  with  three (3) ½" (12 mm) metal screws.  2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together  according to the chimney manufacturer’s instructions.  In many cases, it is recommended to use three  (3) ½" (12 mm) screws. If the offset length is made of two (2) chimney lengths or more, many chimney  manufacturers may require that you use an offset or roof support halfway up the offset. If penetrating a  wall, install a wall radiation shield supplied by the chimney manufacturer.  3. Use another elbow to turn the chimney vertically. Secure the elbow.  4. Use a plumb bob to line up the centre of the hole. Cut a hole for the chimney in the ceiling/floor. Frame  this hole as described previously.  5. From below, install a firestop supplied by the chimney manufacturer (see preceding figure).  6. A support must be used on the first 15' section (4.6 m).  7. Continue with the regular installation.  FP14 Cartier - Installation and Operation Manual...
  • Page 60 6" (15 cm)  American Metal  HS  AC Triple Wall  6" (15 cm)  Olympia Chimney  Ventis  1” Solid Pack  6" (15 cm)  FMI (U.S.A. only)  AC  AC Triple Wall  6" (15 cm)  WARNING: IN EVERY CASE, THE CHIMNEY MUST START WITH A 6'' DIAMETER ANCHOR PLATE SECURED  TO THE FIREPLACE.   *This  fireplace  may  be  installed  with  a  7‐inch  chimney  from  “Security  Chimney”  as  indicated  it  the  table  above.   FP14 Cartier - Installation and Operation Manual...
  • Page 61 Anchor Plate (6SP)  R  NR  R  R  A  Anchor Plate (6XSP)  NR  R  NR  NR  B  Screws  R  R  R  R  C  6″ à 7″ Chimney adaptor (6AW7)  NR  NR  R  R  7″Chimney adaptor, 1″  D  insulation to 2″ insulation  NR  NR  NR  R  (7UCA)      FP14 Cartier - Installation and Operation Manual...
  • Page 62  Chimney  cannot  be  enclosed  at  the  AC  Triple  wall  HS,  American Metal  AC Triple wall HSS  attic level.  *You can get a kit of four (4) rafter protector (AC03510) from  your  dealer.  Each  rafter  is  made  of  22GA  galvanized  steel  (10.44”W x 5.126”H).  1.530” 5.126” 10.44” .512” FP14 Cartier - Installation and Operation Manual...
  • Page 63: Angled Wall Radiation Shield

    GYPROCK  C  INSULATED WALL    8.8 Chimney Support Installation  8.8.1 Universal Roof Support  This support has three possible uses:  1. It must be used on a roof to support the chimney.  2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.  3. It may be used on a floor, ceiling or roof as a supplementary support.  For  roof  support  installation,  refer  to  the  instructions  provided  with  the  support  by  the  chimney  manufacturer.  Many manufacturers will provide the maximum height of chimney that can be supported by    the support. Make sure you respect those parameters. FP14 Cartier - Installation and Operation Manual...
  • Page 64: Universal Offset Support

    2. The clearance to combustible must be a minimum of 1" between the outside of the masonry and any  wood framing or loose insulation.  3. The chimney must be built in accordance with the current building code.  4. No other appliance can be connected to the same chimney.  Installation:  The  chimney  must  be  relined  with  a  stainless  steel  liner  of  the  same  diameter  as  the  outlet  of  the  ° fireplace. For connection at 30  or 45° angle, a special connector (B) must be used to connect the liner (C)  to the insulated chimney (A). Verify availability and installation instructions for this connector with the  chimney manufacturer.  FP14 Cartier - Installation and Operation Manual...
  • Page 65: Supply Of Combustion Air

    The  CO  detector  will  provide  warning  if  for  any  reason  the  wood  fireplace  fails  to  function correctly.  8.10.1 Air Supply in Conventional Houses  The safest and most reliable supply of combustion air for your wood fireplace is from the room in which it is  installed. Room air is already preheated so it will not chill the fire, and its availability is not affected by wind  pressures  on  the  house.  Contrary  to  commonly  expressed  concerns,  almost  all  tightly‐sealed  new  houses  have enough natural leakage to provide the small amount of air needed by the fireplace. The only case in  FP14 Cartier - Installation and Operation Manual...
  • Page 66 In  some  windy  conditions,  negative  pressure  at  the  duct  weatherhood  outside  the  house wall may draw hot exhaust gases from the fireplace backwards through the duct to outdoors. Check  the  outdoor  air  duct  for  soot  deposits  when  the  full  system  is  cleaned  and  inspected  at  least  once  each  year.    FP14 Cartier - Installation and Operation Manual...
  • Page 67: Appendix 1: Optional Hot Air Ducting Installation

    68" (1.7 m)     Maximum length     10' (3m)    Ceiling Clearance    12" (30 cm)    *The  minimum  height  of  the  hot  air  ducting  must  be  measured  from  the  floor  to  the  top  of  the  hot  air  grilles.     FP14 Cartier - Installation and Operation Manual...
  • Page 68   The hot air grilles can be installed in the same room as the fireplace, or one or both of the grilles can be  installed in adjacent or upper rooms. Installing the ducts at different elevations will tend to exhaust more  heat out of the higher grilles.    FP14 Cartier - Installation and Operation Manual...
  • Page 69 The duct system must be installed respecting the following:  1. It is recommended to wear gloves to perform this procedure. Remove the plates closing up the 8" dia.  holes  on  top  of  the  fireplace.  Then,  cut  and  remove  the  insulation  in  order  to  obtain  two  8"  dia.  openings. Then, remove the plates closing up the 8" dia. holes inside the fireplace.       2. Secure the 6 steel brackets (B) with 6 screws provided (C) on top of the fireplace (3 for each ducting).  Insert the ducting (A) (not provided) into each opening and secure it in place using the steel brackets (B)  installed previously with 6 other self‐tapping screws provided (C).          FP14 Cartier - Installation and Operation Manual...
  • Page 70 Secure  hot  air  outlets  (F)  to  the  elbows  (E)  with  3  self‐tapping  screws  each.  Secure the hot air outlets grilles to the frames with screws.                                               FP14 Cartier - Installation and Operation Manual...
  • Page 71   DIMENSIONS OF HOT AIR OUTLET FRAME WITH ELBOW DIMENSIONS OF HOT AIR OUTLET DECORATIVE GRILLE WITH ELBOW     4. Maintain at least a 2" (50 mm) clearance between the ducts and the firestop; the required hole size for  the hot air grilles (outlet) is 8¼" × 8¼" (210 mm × 210 mm).  5. The maximum number of elbows in a run of duct is two.  6. Maintain at least 10" (254 mm) clearance from the outlet grille framing to a combustible ceiling, side  wall or mantel.  FP14 Cartier - Installation and Operation Manual...
  • Page 72   8. Do not connect the hot air ducts to a central heating system. Malfunction of the heating system’s fan  will cause the fireplace to overheat.   9. Do not use insulated flexible ducts as they may overheat.  10. Do not use tees or any other components than the ones specifically listed here.  11. All ducts must extend upwards or horizontally. Never route the ducting downwards.  12. The  hot  air  outlet  grilles  must  be  installed  with  the  louvers  pointing  downwards  in  order  to  prevent  overheating adjacent ceilings.  13. Always install the two outlet grilles when using the hot air outlet kit and blocking the upper louver of  the fireplace.  FP14 Cartier - Installation and Operation Manual...
  • Page 73   Hot air gravity kit - Modern style (AC01385) The kit includes:  Decorative plate (A)   Adjustable frame (B)  Heat distribution box (C)  6 x steel brackets (D) with fastening screws (E) and self‐tapping screws (F)    Parts not included in the kit:  2x 8” rigid ducting (G)                FP14 Cartier - Installation and Operation Manual...
  • Page 74   DIMENSIONS OF HEAT DISTRIBUTION BOX:      DIMENSIONS OF ADJUSTABLE DECORATIVE PLATE:                           FP14 Cartier - Installation and Operation Manual...
  • Page 75 DIMENSIONS OF ASSEMBELED HEAT DISTRIBUTION HOUSING AND ADJUSTABLE DECORATIVE PLATE:    The duct system must be installed respecting the following:  1. It is recommended to wear gloves to perform this procedure. Remove the plates closing up the 8" dia.  holes  on  top  of  the  fireplace.  Then,  cut  and  remove  the  insulation  in  order  to  obtain  two  8"  dia.  openings. Then, remove the plates closing up the 8" dia. holes inside the fireplace.                  FP14 Cartier - Installation and Operation Manual...
  • Page 76   2. Secure the 6 steel brackets (B) with 6 screws provided (C) on top of the fireplace (3 for each ducting).  Insert the ducting (A) (not provided) into each opening and secure it in place using the steel brackets (B)  installed previously with 6 other self‐tapping screws provided (D).        3. Secure the ducting (A) to the heat distribution box (E) with self‐tapping screws (3 per ducting). Insert the  adjustable frame (F) in the heat distribution box, press it against the non‐combustible finishing material and  secure with 4 screws into the heat distribution box. Set the decorative plate (G) to the adjustable frame (F).     FP14 Cartier - Installation and Operation Manual...
  • Page 77 ULC  S110  and/or  UL  181,  Class  0  or  Class  1  Standards  and  must  withstand  temperatures up to 250 °F.  For  the  complete  installation  procedure,  see  the  installation  manual  provided  with  the  kit.  You  can  also  download this manual at www.valcourtinc.com.    FP14 Cartier - Installation and Operation Manual...
  • Page 78: Appendix 2: Blower Maintenance Or Replacement

    1. Open  the  bottom  louver (A).      2. Cut  the  Tie  wrap  (D)  holding  in  place  the  blower (C).   3. Lift  the  blower  (C),  located  under  the  firebox  towards  the  back, and free it from  its pins.      FP14 Cartier - Installation and Operation Manual...
  • Page 79   4. Unplug  the  blower’s  electric  wires  (E)  and  (F).  5. Turn 90° to pull out.    Repeat  the  steps  in  reverse order to reinstall  the fan.        FP14 Cartier - Installation and Operation Manual...
  • Page 80   Connect  the  black  wire  with  the  black  wire  of  the  terminal  block.    The  ground  (green  or  skinned  wire)  must  be  attached  to  the  fireplace metal frame.        FP14 Cartier - Installation and Operation Manual...
  • Page 81: Appendix 3: Installing The Door Overlay Option

    To  facilitate  the  installation,  do  not  tighten  the  nuts  until  they  are  all  installed.  Note:    It  is  not  necessary  to  remove  the  glass  or  any  other  component  to  install the overlay.        FP14 Cartier - Installation and Operation Manual...
  • Page 82: Appendix 4: Installing The Adapter For Fresh Air Kit Option

    THE  OUTSIDE  WALL  TERMINATION  SHOULD  BE  INSTALLED  WHERE  IT  IS  NOT  LIKELY  TO  BE  BLOCKED  BY  SNOW OR EXPOSED TO EXTREME WIND AND AWAY FROM AUTOMOBILE EXHAUST FUMES, GAS METER  AND OTHER VENTS.  The fresh air intake kit included with the fireplace contains the following components:   a. One (1) 4" adaptor;  b. One (1) air inlet block‐off plate;  c. Two (2) screws;     The following component is not included:  a. The outside air inlet cap;  b.  The 2 adjustable straps.  c. A 4” insulated flexible pipe (This HVAC type pipe must comply to ULC S110 and/or UL 181, Class 0 or  Class 1 Standards and must withstand temperatures up to 250 °F.    FP14 Cartier - Installation and Operation Manual...
  • Page 83   Note: Only remove the knock‐out that will be connected to the fresh air inlet.  The fresh air intake kit may be installed on the right hand side of the fireplace.    1. With pliers, remove knockout (A).          2. Attach  the  fresh  air  inlet  adaptor  (B)  on  the right side of the outside jacket using 2  screws (C) supplied with the kit.      FP14 Cartier - Installation and Operation Manual...
  • Page 84 Then  screw  the  block‐off  plate  (G)  just  under the air control arm with the help of  the  two  screws  provided  (H).  Once  in  place, the block‐off plate will ensure that  the  inlet  air  will  enter  through  fresh  air  kit.   *  If  fresh  air  kit  is  not  used,  block‐off  plate should not be used.      FP14 Cartier - Installation and Operation Manual...
  • Page 85 To  complete  the  installation,  make  a  hole  of  1/4"  to  1/2"  (6  mm  à  13  mm)  bigger  than  the  insulate  pipe  diameter in the outside wall of the house at the chosen location. From outside, place the outside air inlet  cap in the hole (open side down) and fasten the register to the wall, with screws as shown bellow. Place the  insulated pipe over the register tube and over the fireplace outside air connector. At each end, carefully pull  back the insulation and plastic cover, exposing the flexible pipe. Attach the flexible pipe using pipe clamps.   For a better seal, you may also use aluminum tape.  Wrap the tape around the joint between the flexible  pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Fix the plastic in  place using aluminum tape.                        FP14 Cartier - Installation and Operation Manual...
  • Page 86: Appendix 5: Installing The Optional Fire Screen (Va8420)

      APPENDIX 5: INSTALLING THE OPTIONAL FIRE SCREEN (VA8420)  Insert the upper part of the fire screen into the  top hinge bracket then insert the lower part of  the  fire  screen  in  the  lower  hinge  bracket.  Repeat for the second door.    Warning: Never leave the stove unattended while in use with the fire screen.  FP14 Cartier - Installation and Operation Manual...
  • Page 87: Appendix 6: Installation Of Secondary Air Tubes And Baffle

    REMOVABLE PARTS  Air tubes  A   (x3)  Air tubes brackets  B  (x3)  Screws  C  (x3)  Stainless steel/concret  D  baffle  (x1)      1. Using a ratchet and a 7/16” (12  mm) hexagonal socket, unscrew  the  two  bolts  (A)  and  remove  the  andiron  (B).  If  necessary,  replace the insulating gasket (C)  under the andiron.    FP14 Cartier - Installation and Operation Manual...
  • Page 88   2. Remove  the  front  refractory  slab (D) and the floor refractory  slab (E).    3. Remove  the  slab  holder  (F)  using  a  1/4"  (7  mm)  hexagonal  socket then remove the left slab  (G).    FP14 Cartier - Installation and Operation Manual...
  • Page 89 Install  the  baffle  then  repeat  steps  4,  5  &  6  for  the  remaining tubes.  To  remove  the  tubes,  follow  the  steps in reverse order.      FP14 Cartier - Installation and Operation Manual...
  • Page 90         Note that secondary air tubes can be replaced without removing the baffle board.  Important Notes:  The air tubes are identified for placement as follows:  Model  Type of tube  FP14 Cartier fireplace  Front ► 59 holes of 0.93"  Middle ► 57 holes of 0.093"  Rear ► 55 holes of 0.093’’            FP14 Cartier - Installation and Operation Manual...
  • Page 91: Appendix 7: Exploded Diagram And Parts List

      APPENDIX 7: EXPLODED DIAGRAM AND PARTS LIST    FP14 Cartier - Installation and Operation Manual...
  • Page 92 1  30  PL60266  LONG TOP STANDOFF  2  31  PL60020  SHORT TOP STANDOFF  2  32  PL61268  REAR STANDOFF  1  33  PL61399  LONG SIDE STANDOFF  2  34  PL63767  SHORT SIDE STANDOFF  4  35  30808  HINGE PIN  2  36  30117  SOCKET SET SCREW #10‐32 X 1/4"  2  37  SE45355  OWNER MANUEL FP14 FIREPLACE  1  FP14 Cartier - Installation and Operation Manual...
  • Page 93 54  PL61262  REAR SECONDARY AIR TUBE  1  55  PL61312  BAFFLE  1  56  AC01375  HOT AIR GRAVITY KIT ‐ TRADITIONAL KIT  1  57  49066  90 DEGREE X 8" 26Ga. GALVANISED ELBOW  2  58  30640  GAKLVANISED BOX FOR HOT AIR GRAVITY KIT 8"  2  59  30540  HOT AIR GRAVITY KIT GRILL  1  60  AC01385  HOT AIR GRAVITY KIT ‐ MODERN STYLE  1  61  AC02022  BLOWER ASSEMBLY  1      FP14 Cartier - Installation and Operation Manual...
  • Page 94 If  large  cracks  develop,  then  the  refractory  slabs  should  be  replaced.  To  replace  the  refractory slabs, follow these steps:  1‐ Using  a  ratchet  and  a  7/16”  (12  mm)  hexagonal  socket,  unscrew  the  two  bolts (A) and remove the andiron (B). If  necessary, replace the insulating gasket  (C) under the andiron.  2‐ Remove  the  front  refractory  slab  (D)  and floor refractory slab (E).      FP14 Cartier - Installation and Operation Manual...
  • Page 95   3‐ Using  a  power  screwdriver  and  a  1/4"  (7  mm)  hex  tip,  remove  the  slab  holders (F) and the side refractory slabs  (G) and (H).  4‐ Remove the rear refractory slab (I).  To  install  new  refractory  slabs,  follow  the  above steps in reverse.      FP14 Cartier - Installation and Operation Manual...
  • Page 96: Valcourt Limited Lifetime Warranty

    Carbon steel firebox components, glass retainers, and handle assembly.  3 years  2 years  Blowers, heat sensors, switches, rheostat, wiring, and other controls.  2 years  1 year  Paint (peeling), gaskets, insulation, firebrick, and ceramic fibre blankets.  1 year  n/a  *Pictures required  Shall your unit or a components be defective, contact immediately your VALCOURT dealer. Prior to your call make sure you have  the following information necessary to your warranty claim treatment:    Your name, address and telephone number;   Serial  number  and  model  name  as  indicated  on  the  nameplate fixed to the back of your unit;   Bill of sale and dealer’s name;   Nature of the defect and any relevant information.    Before shipping your unit or defective component to our plant, you must obtain from your VALCOURT dealer an Authorization  Number. Any merchandise shipped to our plant without authorization will be refused automatically and returned to sender.    FP14 Cartier - Installation and Operation Manual...