8.6.6 Replacing thermoblock with NTC sensor and fine
wire fuse(s)
A defect thermoblock can only be replaced with an assembly consisting of
-
thermoblock, prewired with NTC temperature sensor, fine wire fuse(s) and ground
wire (only if required),
-
thermoblock support.
•
Release 3 latches and pull out support with thermoblock assembly (15).
R E P A I R S
15
Citiz service manual
Depending on
national regulations,
one or two fine wire
fuses are mounted on the
thermoblock (see "Wiring
diagrams" on page 97 and
following).
Do not stress NTC
cable when remov-
ing support.
83