8.7.2 Replacing electronic control board with button prints
1
•
Refer to page 93 for removing cover (2).
42
•
Remove first
- NTC connector from electronic control board,
- connector cable from flow meter,
- electronic lid (43),
- faston receptacles from electronic control board.
•
Insert tip of screwdriver between chassis (1) and protective case of electronic control
board (42) to release latches. Then pull out assembly.
2
43
11
Citiz service manual
R E P A I R S
12
42
The replacement
board (42) is
equipped with protec-
tive housing and cover.
95