Download Print this page

Sharp VL-PD1U Service Manual page 63

Liquid crystal digital camcorder

Advertisement

VL-PDl U
EE output
Address:
"0018" INDOOR W/BR
"001 A" INDOOR W/BR
Measuring
instrument:
Vector scope
Object:
G rey scale
Data variation
width:
"0000" to "03FF"
(1) Colour gain adjustment
is performed
repeatedly.
Address:
"012B" CGIN RYG
"012D" CGIN BYG
"0128" CMAT RYG
"0126" CMAT BYG
Measuring
instrument:
Vector scope
Object:
Waveform
monitor
colour
bar
chart
Data variation
width:
"0000" to "OOFF"
Red amplitude
Blue amplitude
Adjustment
address
1.60 k 0.05 time (burst ratio)
: "012B"
1 .I 5 + 0.05 time (burst ratio)
: "012D"
103O + I"
n
"0128"
.
344" + 2"
= "0126"
.
(9)Auto white balance adjustment
l
Measurement
terminal:
EE output
l
Address:
"006A" OUTDOOR
R
"006C" OUTDOOR
B
l
Measuring
instrument:
Vector scope
l
Object:
G rey scale
l
Data variation
width:
"0000" to "03FF"
(l)The
colour temperature
conversion
filter (LB1 65) is mounted in front of lens.
(2) Indication of vector scope is observed in the grey scale standard record state,
and an adjustment
is made so that the luminous
dots are located
in the
following
positions:
R-Y 0 + 5% (burst ratio)
B-Y 0 + 5% (burst ratio)
After completion
of adjustment
set the regular operation
mode (the data " ..' _: .I,,: FF" is written in the address "OOBO".)
1 o-22