10.0 Changing Components – Page 20
Supplied By www.heating spares.co Tel. 0161 620 6677

10.1 Changing Components

WARNING: Before changing any components, ensure
that the stove is cool and that the gas supply is isolated.
10.2 Spillage Monitoring Device
(Figs. 43 & 44)
1.
Undo the nut and screw holding the monitoring device
sensor bracket to the draught diverter.
2.
Withdraw the sensor from the bracket.
3.
Pull the two wires off the sensor body and undo the
screws holding the body to the appliance.
4.
Remove the spillage monitoring device from the
appliance.
5.
Refit the new device in reverse order, carefully routing
the capillary so as it does not touch any hot panels.
WARNING: The spillage monitoring device must not be
adjusted in any way. The spillage monitoring device
must not be altered so that it will not operate or be
bypassed in any way. Always use a Genuine Baxi Spare
Part.
TO CHANGE ANY GAS CONTROL COMPONENTS. IT IS
NECESSARY TO REMOVE THE COMPLETE CONTROLS
ASSEMBLY. SEE SUB-SECTION 9.2 PREPARATION OF
9.0 ANNUAL SERVICING