11. AD DATA

The sub-menu of this menu displays the A/D conversion value of the CPU (operation circuit board IC501) which
detects the keys and protection functions of the main unit in %. (reference voltage 5V: 100%)
When in KY0/KY1/KY2 page, it is not possible to operate the keys of the main unit because the values of all keys
are detected. But one click on the VOLUME of the main unit will cancel this function and sets to the next sub-menu.
The signal processing state remains the same as that before executing this menu.
K0:100 K1:100
K2:100 PL:020
DC:007 PS:025
The above figures are ex-
amples for reference.
KY0/KY1 (Detection of key scan)[Remote control code: – – – – ]
KY0/KY1: Panel key of the main unit (10% step)
KY2/PL (Detection of key scan/Power limit)[Remote control code: – – – – ]
KY2: Panel key of the main unit (10% step)
PL: The value of the power limit (10% step)
• When the standard value is deviated by ±4%, KEY A/D fails to function properly. In this case,
check the circuit voltages, soldering condition, etc.
Indicate
KY0
0
10
20
30
40
50
60
70
80
90
100
KEY OFF state
DC/PS (Detection of the protection function) [Remote control code: 7A—0B (CD SKIP –)]
DC: Protection value for DC detection (Normal value: 1~13) 0.05V~ 0.65V (reference voltage)
When the value is out of the normal value range, the protection function works to turn
off the power.
PS:
Protection value for power voltage (Normal value: 23~37) 1.15V~ 1.85V (reference voltage)
When the value is out of the normal value range, the protection function works to turn
off the power.
Indicate
KY1
0
SET MENU
10
DSP PROGRAM
20
EFFECT
30
40
50
60
70
80
90
100
KEY OFF state
DSP-AX620
Indicate
KY2
0
INPUT MODE
10
INPUT q
20
INPUT w
30
6CH INPUT
40
50
60
70
80
90
100
KEY OFF state