Disturbance or System Attention LED

The system attention LED on the operator panel is turned on when an entry is made in the service
processor error log that is transmitted to the system-level error logs (the AIX error log and the service
action event log in the Service Focal Point application). When the attention light comes on, examine these
error logs to see if user intervention is required.
If a hardware problem is indicated, call service support. If no intervention is required, the system attention
LED can be turned off by either of the following methods:
v On the HMC's graphical interface, as follows:
1. Click on the Service Applications icon.
2. Double-click the Service Focal Point icon.
3.
In the Contents area, select Hardware Service Functions. The LED Management window opens.
4.
In the LED Management window, select one or more managed systems from the table.
5. Select Deactivate LED. The associated system attention LED is turned off.
For more information about the operator panel as it relates to the HMC, see the IBM Hardware
Management Console for pSeries Installation and Operations Guide, order number SA38-0590.
v
As a user with root authority, enter diag on an AIX command line and do the following:
1. Select Task Selection.
2. On the task selection menu, select Identify and Attention Indicators.
3. When the list of LEDs displays, use the cursor to highlight Set System Attention Indicator to
Normal.
4. Press Enter, and then press F7 to commit. This action turns off the LED.
v If the system is powered off, access the service processor menus and from the main menu, do the
following:
1. Select System Information Menu.
2. Select LED Control Menu.
3. Select Clear System Attention Indicator. This action turns off the LED.
For more information regarding the LED, refer to "Component LEDs" on page 16.