Water Valve; Thermostats And Mounting Bracket - Electrolux FMB330RGB0 Service Manual

2007 18 inch built-in dishwasher
Table of Contents

Advertisement

5.
Go to top corner and form seal into corner, then
tack seal into channel down side.
6.
Repeat for opposite side.
7.
Close door to seat seal into channel.

Water Valve

1.
Disconnect power to dishwasher.
2.
Remove toe kick and outer door panel.
3.
Turn off water supply to dishwasher then place
protection under water line that attaches to the
water valve to catch water that will be in the line.
4.
Two screws hold valve to frame.
5.
Disconnect wires from valve. Terminals have locks
press down on lock to remove terminal.
6.
Remove fill hose from valve.
7.
Install in reverse order.
Mounting scews
Power connections

Thermostats and Mounting Bracket

New thermostats will come with a new mount.
note
It maybe possible to replace the thermostats with the
dishwasher installed under the counter by removing the
front top frame rail. Access to the thermostats can be
gained by first removing the top rail that mounts between
the left and right front frames. To remove this rail first
turn off the water to the unit and disconnect power then
remove the water valve along with the junction box then
the two mounting screws securing on each side of the
rail securing it to the frames. See front frame and rail
configuration on next page.
1.
Disconnect power to dishwasher.
2.
Remove as much water as possible from sump.
3.
Remove toe kick and outer door panel.
4.
Turn off water supply to dishwasher, then place
protection under water line that attaches to the
water valve to catch water that will be in the line as
supply line is removed from the water valve.
5.
Access repair per note above or remove unit from
under counter top.
6.
If unit was removed, lay units on it back. Make sure
there is protection for the floor before unit is laid
down.
7.
Disconnect disconnect block to remove
thermostats.
8.
Remove thermostats and mount from sump.
9.
Remove the four wires from the thermostats. To
remove terminals with locks, press down on lock.
10.
Apply Thermal mastic to head of new thermostats
before installing onto sump.
11.
Reconnect wires to thermostats.
12.
Install thermostat and mount assembly onto sump.
13.
Complete repairs in reverse order.
13
Disconnect block
for thermostats
Thermostats
mounted to
the sump

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmb330rgc0Fmb330rgs0

Table of Contents